Anaesthesia
-
Comparative Study
Pressure generated during insertion of lumbar epidurals. A comparison with the Portex epidural injection simulator.
The aim of this study was to measure pressures exerted during insertion of lumbar epidurals in obstetric patients. The pressures were compared with those obtained when the Portex epidural injection simulator was used, and were significantly greater when a saline technique was used compared to those when air was used (p less than 0.05). There were no differences between the pressures obtained with the simulator and those measured in vivo.
-
Comparative Study
Paraesthesia with lumbar epidural catheters. A comparison of air and saline in a loss-of-resistance technique.
The epidural space was located in 32 obstetric patients using loss of resistance to air, while in a further 35 saline was used. The incidence of paraesthesia was 56% in the air group and 57% in the saline group. There was no significant difference between the groups in terms of other complications or in the quality of analgesia provided.
-
Randomized Controlled Trial Clinical Trial
A randomised double-blind study of interpleural analgesia after cholecystectomy.
Continuous interpleural analgesia provided by 4 hourly injections of 20 ml bupivacaine 0.5% with adrenaline 5 micrograms/ml was compared with placebo in a randomised, double-blind study after cholecystectomy. All patients self-administered intravenous morphine using a patient-controlled analgesia device. There was a highly significant difference in mean morphine consumption between the groups (72 mg as compared with 22 mg). ⋯ The mean peak venous plasma bupivacaine concentration after the sixth dose was 3.03 micrograms/ml and no symptoms suggestive of local anaesthetic toxicity occurred. It is concluded that this regimen can provide effective and continuous analgesia after cholecystectomy and that combined administration of interpleural bupivacaine and systemic morphine is more effective than morphine alone in the immediate postoperative period. The doses of bupivacaine required for optimal use of the technique lead to significant total plasma bupivacaine concentrations within 24 hours.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Obstetric epidural analgesia with mixtures of bupivacaine, adrenaline and fentanyl.
We performed a double-blind comparison of six solutions for epidural analgesia in 90 healthy Chinese women with uncomplicated pregnancies. Patients were randomly allocated to receive 10 ml bupivacaine 0.125% or 0.25% plain, bupivacaine 0.125% with adrenaline 1.25 micrograms/ml, bupivacaine 0.25% with adrenaline 2.5 micrograms/ml or the latter two solutions with added fentanyl 50 micrograms. ⋯ There were no differences in method of delivery or neonatal Apgar scores among groups. The least concentrated mixture that gave the best analgesia was the combination of bupivacaine 0.125% with adrenaline 1.25 micrograms/ml and fentanyl 50 micrograms.
-
Clinical Trial Controlled Clinical Trial
Use of the oesophageal detector device in children under one year of age.
The efficacy of a modified oesophageal detector device was evaluated in a single-blind study of 20 healthy infants. It was found to be unreliable as a method to discriminate oesophageal from tracheal intubation in this age group.