Audiology & neuro-otology
-
Audiology & neuro-otology · Jan 2020
Chronic Electrical Stimulation of the Otolith Organ: Preliminary Results in Humans with Bilateral Vestibulopathy and Sensorineural Hearing Loss.
Bilateral vestibulopathy is an important cause of imbalance that is misdiagnosed. The clinical management of patients with bilateral vestibular loss remains difficult as there is no clear evidence for an effective treatment. In this paper, we try to analyze the effect of chronic electrical stimulation and adaptation to electrical stimulation of the vestibular system in humans when stimulating the otolith organ with a constant pulse train to mitigate imbalance due to bilateral vestibular dysfunction (BVD). ⋯ Prosthetic implantation of the otolith organ in humans is technically feasible. Electrical stimulation might have potential effects on balance and this is stable after 1 year follow-up. This research provides new possibilities for the development of vestibular implants to improve gravito-inertial acceleration sensation, in this case by the otoliths stimulation.
-
Audiology & neuro-otology · Jan 2019
Case ReportsMRI Metal Artifact Reduction Sequence for Auditory Implants: First Results with a Transcutaneous Bone Conduction Implant.
Magnetic resonance imaging (MRI) is often limited in patients with auditory implants because of the presence of metallic components and magnets. The aim of this study was to evaluate the clinical usefulness of a customized MRI sequence for metal artifact suppression for patients with implants in the temporal bone region, specifically patients with a transcutaneous bone conduction implant. ⋯ The sequence for metal artifact reduction optimized in Bern enables MRI at 1.5 T in patients with active transcutaneous bone conduction implants without sacrificing diagnostic imaging quality. Particularly on the implanted side, imaging of intracranial and supra- and infratentorial brain pathologies is clinically more valuable than standard diagnostic MRI without any artifact reduction sequences.
-
Audiology & neuro-otology · Jan 2016
Comparative StudyComparison of Alternative Coupling Methods of the Vibrant Soundbridge Floating Mass Transducer.
The active middle ear implant Vibrant Soundbridge© provides a variety of coupling modalities of the floating mass transducer (FMT) to various structures of the ossicular chain and the round window. A retrospective analysis was performed on 125 subjects (n = 137 ears) (1) to compare the efficacy of the different FMT coupling modalities with increasing degree of hearing loss, (2) to compare the performance in speech outcome and the effective gain between the coupling types, and (3) to evaluate the risk of additional hearing loss of each coupling procedure. The patients were grouped according to their type of FMT coupling into incus vibroplasty (incus group, n = 59), round window vibroplasty with coupler (RWC group, n = 23), round window vibroplasty without coupler (RW group, n = 22), and oval window vibroplasty with coupler (OWC group, n = 33). ⋯ However, the median WRS was 80% or better with no significant differences in speech perception between coupling types (Kruskal-Wallis test, p = 0.229). The effective gain shows an advantage for the incus coupling between 0.5 and 2 kHz over the other coupling types. The performance of the FMT coupling modalities is equally good for patients with a mild-to-moderate hearing loss, but the efficacy of coupling types differs for patients with greater hearing loss (>48 dB BC HL).
-
Audiology & neuro-otology · Jan 2014
Separating the contributions of olivocochlear and middle ear muscle reflexes in modulation of distortion product otoacoustic emission levels.
Mediated by the medial olivocochlear system (MOCS), distortion product otoacoustic emission (DPOAE) levels are reduced by presentation of contralateral acoustic stimuli. Such acoustic signals can also evoke a middle ear muscle reflex (MEMR) that also attenuates recorded DPOAE levels. Our aim is to clearly differentiate these two inhibitory mechanisms and to analyze each separately, perhaps allowing the development of novel tests of hearing function. ⋯ Following middle ear muscle tendon division, DPOAE inhibition by contralateral stimuli approximating the primary tone f2 persists, whereas responses evoked by lower contralateral frequencies are abolished. This distinguishes the different roles of the MOCS (f2 frequency specific) and MEMR (low frequency only) in contralateral modulation of DPOAE. This analysis helps clarify the pathways involved in an objective test that might have clinical benefit in the testing of neonates.
-
Audiology & neuro-otology · Jan 2014
Alternative fixation of an active middle ear implant at the short incus process.
Since 1996, the preferred approach for positioning the active middle-ear implant Vibrant Soundbridge© is a mastoidectomy and a posterior tympanotomy. With this device, placement of the floating mass transducer (FMT) on the long incus process is the standard method for treatment of mild-to-severe sensorineural hearing loss in the case of normal middle-ear anatomy. The aim of this study was to determine the vibrational effectiveness of FMT placement at the short incus process. ⋯ Coupling the FMT to the short incus process may be a viable alternative in cases where the surgical approach is limited to an extended antrotomy. A reliable technique for attachment to the short incus process has yet to be developed.