British journal of anaesthesia
-
Randomized Controlled Trial Comparative Study
Comparison of efficacy of oxybutynin and tolterodine for prevention of catheter related bladder discomfort: a prospective, randomized, placebo-controlled, double-blind study.
Bladder discomfort related to intraoperative catheterization of urinary bladder is a distressing symptom and more so in patients awakening from anaesthesia. These symptoms are similar to symptoms of overactive bladder. Muscarinic receptor antagonists have been reported to be effective in the treatment of overactive bladder. This study was therefore undertaken to evaluate the efficacy of oxybutynin and tolterodine in preventing catheter related bladder discomfort. ⋯ Pretreatment with either oxybutynin or tolterodine reduces the incidence and severity of catheter related bladder discomfort.
-
Randomized Controlled Trial
Large volume N2O uptake alone does not explain the second gas effect of N2O on sevoflurane during constant inspired ventilation.
The second gas effect (SGE) is considered to be significant only during periods of large volume N(2)O uptake (VN(2)O); however, the SGE of small VN(2)O has not been studied. We hypothesized that the SGE of N(2)O on sevoflurane would become less pronounced when sevoflurane administration is started 60 min after the start of N(2)O administration when VN(2)O has decreased to approximately 125 ml min(-1), and that the kinetics of sevoflurane under these circumstances would become indistinguishable from those when sevoflurane is administered in O(2). ⋯ We confirmed the existence of a SGE of N(2)O. Surprisingly, when using an Fa of 65% N(2)O, the magnitude of the SGE was the same with large or small VN(2)O. The classical model and the graphical representation of the SGE alone should not be used to explain the magnitude of the SGE. We speculate that changes in ventilation/perfusion inhomogeneity in the lungs during general anaesthesia result in a SGE at levels of VN(2)O previously considered by most to be too small to exert a SGE.
-
Randomized Controlled Trial
Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation.
Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. ⋯ Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.
-
Randomized Controlled Trial
Combined use of Bispectral Index and A-Line Autoregressive Index to assess anti-nociceptive component of balanced anaesthesia during lumbar arthrodesis.
This study evaluated the A-Line Autoregressive Index (AAI) response to surgical stimulation during lumbar arthrodesis, as an estimate of the anti-nociceptive component of a Bispectral Index (BIS) guided anaesthesia combined with epidural analgesia. ⋯ During a BIS-guided constant level of hypnosis, AAI response to the onset of surgical stimulation significantly differs according to the analgesic regimen. Further studies are needed to refine the estimation of sensitivity and specificity of this variable in assessing the balance between nociception and anti-nociception during general anaesthesia.