British journal of anaesthesia
-
Comparative Study Observational Study
Bilateral bispectral index monitoring during and after electroconvulsive therapy compared with magnetic seizure therapy for treatment-resistant depression.
Electroconvulsive therapy (ECT) is a highly effective and established treatment for depression. Magnetic seizure therapy (MST) has recently been developed and seems equally effective while associated with fewer side-effects. Both require general anaesthesia, which could be quantified using the bispectral index (BIS). We compared ECT and MST with respect to recovery times, left-sided BIS, and left-right differences in BIS. ⋯ At a comparable anaesthetic depth, MST is superior to ECT in terms of post-ictal recovery, which is correctly reflected by higher post-ictal BIS values. Unilateral BIS monitoring is sufficient to monitor anaesthetic depth in ECT and MST patients. TRIAL REGISTRY NUMBER: NCT 01318018.
-
We report on a rare complication of poly(methyl methacrylate) (PMMA), injected into the spine, which then inadvertently leaked into the venous system. This resulted in an embolism of PMMA and produced a mass surrounding a triple lumen central venous catheter located in the superior vena cava. The catheter as well as the attached mass of PMMA was retrieved safely by cardiothoracic surgery. This case emphasizes the importance of prompt diagnosis and treatment and illustrates the need for close monitoring of patients undergoing any spinal surgery that includes vertebroplasty.
-
The FloTrac/Vigileo™, introduced in 2005, uses arterial pressure waveform analysis to calculate cardiac output (CO) and stroke volume variation (SVV) without external calibration. The aim of this systematic review is to evaluate the performance of the system. Sixty-five full manuscripts on validation of CO measurements in humans, published in English, were retrieved; these included 2234 patients and 44,592 observations. ⋯ have been analysed according to underlying patient conditions, that is, general critical illness and surgery as normodynamic conditions, cardiac and (post)cardiac surgery as hypodynamic conditions, and liver surgery and sepsis as hyperdynamic conditions, and subsequently released software versions. Eight studies compared SVV with other dynamic indices. CO, bias, precision, %error, correlation, and concordance differed among underlying conditions, subsequent software versions, and their interactions, suggesting increasing accuracy and precision, particularly in hypo- and normodynamic conditions. The bias and the trending capacity remain dependent on (changes in) vascular tone with most recent software. The SVV only moderately agreed with other dynamic indices, although it was helpful in predicting fluid responsiveness in 85% of studies addressing this. Since its introduction, the performance of uncalibrated FloTrac/Vigileo™ has improved particularly in hypo- and normodynamic conditions. A %error at or below 30% with most recent software allows sufficiently accurate and precise CO measurements and trending for routine clinical use in normo- and hypodynamic conditions, in the absence of large changes in vascular tone. The SVV may usefully supplement these measurements.