British journal of anaesthesia
-
Awareness occurred in 1 in 19,000 general anaesthetics, resulting in distress in 51% of cases and longterm harm in 41%. BIS monitoring was used in 5% of cases of awareness.
summary -
We present the main findings of the 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia (AAGA). Incidences were estimated using reports of accidental awareness as the numerator, and a parallel national anaesthetic activity survey to provide denominator data. The incidence of certain/probable and possible accidental awareness cases was ~1:19,600 anaesthetics (95% confidence interval 1:16,700-23,450). ⋯ The following factors were not risk factors for accidental awareness: ASA physical status, race, and use or omission of nitrous oxide. We recommend that an anaesthetic checklist, to be an integral part of the World Health Organization Safer Surgery checklist, is introduced as an aid to preventing accidental awareness. This paper is a shortened version describing the main findings from NAP5--the full report can be found at http://www.nationalauditprojects.org.uk/NAP5_home.
-
We aimed to create a theoretical tool to model the effect of three haemostatic agents containing fibrinogen (therapeutic plasma, cryoprecipitate, and fibrinogen concentrate) on the patient's plasma fibrinogen level. ⋯ We successfully developed two theoretical tools answering the questions: 'How much therapeutic plasma, cryoprecipitate, or fibrinogen concentrate would be needed to achieve a specified target fibrinogen level?' and 'What would be the resultant fibrinogen level for a specified amount of haemostatic agent?' The current tools are not intended for clinical application, but they are potentially useful for educational purposes.