British journal of anaesthesia
-
Single-injection paravertebral block offers adequate unilateral analgesia for thoracic and upper abdominal surgery. This technique is easy to learn but there is a risk, albeit low, of pleural puncture. The aim of the study was to determine whether sonographic measurements of the distances from the skin to the transverse process and to the parietal pleura are useful for calculating the required depth of needle insertion. ⋯ Puncture of the paravertebral space failed in one obese woman. There was a very close correlation between needle insertion depth from the skin to the transverse process and the distance measured by ultrasound if angle correction was used (adjusted r2=0.95). Similarly, there was excellent correlation between the angle-corrected ultrasound distance from the skin to the parietal pleura and the distance from the skin to the paravertebral space (adjusted r2=0.92).
-
Case Reports
Prolonged vecuronium neuromuscular blockade associated with Charcot Marie Tooth neuropathy.
Charcot Marie Tooth (CMT) disease comprises a group of disorders characterized by progressive distal muscle weakness and wasting. Review of the anaesthetic literature produced conflicting reports concerning the responses to neuromuscular blocking drugs in these patients. We describe a case in which vecuronium 0.11 mg kg(-1) produced prolonged neuromuscular blockade lasting 115 min in a patient with the condition. ⋯ This nerve may be more useful in monitoring neuromuscular blockade, both in titrating the dose of neuromuscular blocking drug and ensuring adequate reversal at the end of a procedure. Recent advances in molecular biology have enabled identification of the underlying genetic abnormalities and pathophysiology of CMT. These advances are reviewed and implications of CMT for the anaesthetist discussed.
-
Randomized Controlled Trial Clinical Trial
Prevention of postoperative nausea and vomiting by continuous infusion of subhypnotic propofol in female patients receiving intravenous patient-controlled analgesia.
In this prospective, randomized, double-blind, placebo-controlled study, the use of continuous subhypnotic propofol infusion as an antiemetic in fentanyl intravenous patient-controlled analgesia (i.v. PCA) was investigated during the first 24 h after surgery. One hundred female patients, ASA I-II, aged 20-71 yr, undergoing major gynaecological or orthopaedic surgery, were included. ⋯ PCA was started in the postanaesthesia care unit for postoperative analgesia. Significantly more of the patients given propofol 15 and 20 microg kg(-1) min(-1) experienced no nausea or vomiting compared with those given placebo (65% and 70% versus 25%; P<0.05). Patients given propofol 20 microg kg(-1) min(-1) reported more sedation than those in the other groups 4 h after surgery (P<0.05).
-
Randomized Controlled Trial Comparative Study Clinical Trial
Ropivacaine 0.2% versus bupivacaine 0.1% with fentanyl: a double blind comparison for analgesia during labour.
We have performed a randomized, double-blind comparison of two epidural drug regimens for analgesia in labour. In the bupivacaine group (BUPIV), 101 healthy parturients received 0.1% bupivacaine with fentanyl 2 microg ml(-1). In the ropivacaine group (ROPIV), 102 women received 0.2% ropivacaine. ⋯ The ropivacaine group was more likely to be pain free in the first stage (51% vs. 33.7%, P=0.01). There were no significant differences in patients' assessment of motor block or mode of delivery between the groups. Pain relief and satisfaction scores from midwives and patients were consistently better in the ropivacaine group, but did not reach statistical significance.
-
Randomized Controlled Trial Clinical Trial
Model-based automatic feedback control versus human control of end-tidal isoflurane concentration using low-flow anaesthesia.
We studied the clinical use of an automatic feedback control system to adjust the end-tidal anaesthetic concentration with a low-flow method. The end-tidal controller uses two input signals (the end-tidal and inspiratory concentrations) to control the isoflurane concentration in the fresh gas flow, using a model-based algorithm. We studied 22 ASA I-III patients during elective surgery lasting more than 2 h. ⋯ The automatic control system was more accurate and stable than the human controller for step increases and step decreases, with less overshoot/undershoot and greater stability [e.g. maximal overshoot 14.7 (SD 3.7)% and 18 (8.1)% respectively for +0.6 vol% step changes, and 19.8 (3.7)% and 30.7 (13.2)% respectively for +0.3 vol% step changes]. However, the automatic control system showed a faster response time than the manual method only with large increasing steps (e.g. 149 (32) s and 205 (57) s respectively for +0.6 vol% step changes) and was not different from manual control for decreasing steps. Automatic control of the end-tidal isoflurane concentration can be better than human control in a clinical setting, and this task could be done automatically.