Hernia : the journal of hernias and abdominal wall surgery
-
Randomized Controlled Trial Multicenter Study Comparative Study
Randomized controlled multicenter international clinical trial of self-gripping Parietex™ ProGrip™ polyester mesh versus lightweight polypropylene mesh in open inguinal hernia repair: interim results at 3 months.
To compare clinical outcomes following sutureless Parietex™ ProGrip™ mesh repair to traditional Lichtenstein repair with lightweight polypropylene mesh secured with sutures. ⋯ Surgery duration, early postoperative, pain and infection rates were significantly reduced with self-gripping polyester mesh compared to Lichtenstein repair with polypropylene mesh. The use of fixation increased postoperative pain in the P group. The absence of early recurrence highlights the gripping efficiency effect.
-
Randomized Controlled Trial Comparative Study
Lichtenstein, prolene hernia system, and UltraPro Hernia System for primary inguinal hernia repair: one-year outcome of a prospective randomized controlled trial.
The optimal technique for open inguinal hernia repair is yet to be determined. ⋯ The Lichtenstein technique, PHS, and UHS seem all acceptable approaches for open inguinal hernia repair in local anesthesia and day-care surgery regarding perioperative course, rehabilitation, complications, recurrence rates, development of chronic groin pain, and improvement in quality of life after 12 months. However, due to reduced costs and lack of need for the exploration of the preperitoneal space, the Lichtenstein technique should be recommended as first choice.