Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2024
Randomized Controlled TrialThe impact of a lung-protective ventilation mode using transpulmonary driving pressure titrated positive end-expiratory pressure on the prognosis of patients with acute respiratory distress syndrome.
This study aimed to assess the impact of a lung-protective ventilation strategy utilizing transpulmonary driving pressure titrated positive end-expiratory pressure (PEEP) on the prognosis [mechanical ventilation duration, hospital stay, 28-day mortality rate and incidence of ventilator-associated pneumonia (VAP), survival outcome] of patients with Acute Respiratory Distress Syndrome (ARDS). ⋯ Lung-protective mechanical ventilation using transpulmonary driving pressure titrated PEEP effectively improves lung function, reduces mechanical ventilation duration and hospital stay, and enhances survival outcomes in patients with ARDS. However, further study is needed to facilitate the wider adoption of this approach.
-
J Clin Monit Comput · Dec 2024
Randomized Controlled TrialEffect of continuous measurement and adjustment of endotracheal tube cuff pressure on postoperative sore throat in patients undergoing gynecological laparoscopic surgery: a randomized controlled trial.
Postoperative sore throat (POST) is a common complication following endotracheal tube removal, and effective preventive strategies remain elusive. This trial aimed to determine whether actively regulating intraoperative cuff pressure below the tracheal capillary perfusion pressure threshold could effectively reduce POST incidence in patients undergoing gynecological laparoscopic procedures. ⋯ Continuous monitoring and maintenance of tracheal tube cuff pressure at 18 mmHg were superior to merely monitoring without adjustment, effectively reducing the incidence of POST during quiet within 24 h after tracheal tube removal in gynecological laparoscopic surgery patients.
-
J Clin Monit Comput · Dec 2024
Randomized Controlled TrialEffects of hand catalepsy on subjective trance perception and relative parasympathetic tone in healthy volunteers during pleasant hypnotic session: a randomized controlled study.
This study was designed to evaluate the effects on hand catalepsy on parasympathetic tone assessed using Analgesia/Nociception Index (ANI) and on subjective rating of absorption, dissociation, and time perception among healthy volunteers. This was a randomized controlled trial including participants to a medical hypnosis congress in France. Ninety volunteers were randomized in two arms, all receiving a fifteen-minute positive hypnotic trance, with or without hand catalepsy. ⋯ Parasympathetic comfort increased during the hypnotic trance with no difference between groups. However, adding hand catalepsy to a pleasant hypnotic trance did not appear to increase feelings of absorption or dissociation but created time distortion on the longer side that could be useful in some clinical settings. Nevertheless, further study is still needed to determine more precisely the physiological and psychological effects on hand catalepsy during the hypnotic trance.
-
J Clin Monit Comput · Dec 2024
Randomized Controlled Trial Comparative StudyComparing the haemodynamic effects of high- and low-dose opioid anaesthesia: a secondary analysis of a randomised controlled trial.
Post-induction hypotension (MAP < 65 mmHg) occurs frequently and is usually caused by the cardiovascular adverse effects of the anaesthetic induction drugs used. We hypothesize that a clinically significant difference in the incidence and severity of hypotension will be found when different doses of propofol and remifentanil are used for induction of anaesthesia. ⋯ Induction of anaesthesia with different predicted equipotent combinations of propofol and remifentanil did result in statistically different but clinically irrelevant differences in haemodynamic endpoints during induction of anaesthesia. Our study could not identify preferable drug combinations that decrease the risk for hypotension after induction, although they all yield a similar predicted PTOL.
-
J Clin Monit Comput · Oct 2024
Randomized Controlled Trial Comparative StudyComparison of automated and manual control methods in minimal flow anesthesia.
New-generation anesthesia machines administer inhalation anesthetics and automatically control the fresh gas flow (FGF) rate. This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mindray A9 (Shenzhen, China) anesthesia machine versus manual control by an anesthesiologist. ⋯ The ACA mode was more advantageous than the MCA mode, reaching target AA concentrations faster and requiring fewer adjustments to achieve a constant depth of anesthesia.