Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jul 2002
Comparative StudyActivated clotting time systems vary in precision and bias and are not interchangeable when following heparin management protocols during cardiopulmonary bypass.
Our aim was to test the hypothesis that new activated clotting time (ACT) technology, with modifications to instruments and reagents designed to detect earlier clot formation, would be associated with more precise but lower results. A secondary objective was to evaluate the potential impact of any change in ACT measurement on heparin requirements during cardiopulmonary bypass (CPB). ⋯ Our results support the hypothesis that the modified technology (Actalyke) is associated with more precise but lower ACT results. We estimated these lower values would lead to increased heparin dosing during CPB. The impact of this increase on bleeding after cardiac surgery with CPB is controversial and requires further study.
-
J Clin Monit Comput · Jul 2002
Subcutaneous microdialysis for metabolic monitoring in abdominal aortic surgery.
Microdialysis, that is the sampling of interstitial fluid via semi-permeable tubes, has been shown to be suitable for detecting ischemic changes e.g. in brain and heart tissue. The purpose of the present study was to investigate the possibility of monitoring with subcutaneous microdialysis peri-operative metabolic sequelac of elective abdominal aortic surgery. In 22 patients microdialysis catheters were inserted subcutaneously in the lower leg as well as the shoulder serving as a reference topographic region. Lactate, pyruvate and glycerol, which indicate ischemia or reperfusion, were measured. We observed severe metabolic changes within the interstitial fluid of the lower extremity during ischemia followed by normalization during reperfusion. Despite high interstitial concentrations of lactate and glycerol indicating severe ischemia during clamping of the abdominal aorta these parameters returned to pre-operative values within 2 hrs after declamping and all patients recovered completely. ⋯ Subcutaneous microdialysis was able to detect metabolic changes due to ischemia during clamping of the abdominal aorta as well as reperfusion there after. It is a suitable technique to monitor the peri-operative course of the dependent tissue after abdominal aortic vascular surgery.
-
J Clin Monit Comput · Jul 2002
Case ReportsMonitoring of motor evoked potentials with high intensity repetitive transcranial electrical stimulation during spinal surgery.
Clinical utility of high voltage repetitive transcranial electrical stimulation (TES) was investigated in 46 patients undergoing spine surgery. ⋯ The findings suggest that intraoperative MEP monitoring is feasible method, however, its immediate prognostic value for adequacy of neuronal decompression and improvement requires further studies with larger patient population.
-
J Clin Monit Comput · Jul 2002
Bispectral Index in ICU: correlation with Ramsay Score on assessment of sedation level.
The assessment of sedation level in critically ill patient remains a challenge for the intensivists in order to avoid over- or under-sedation phenomena. Scoring systems commonly used still show some limitation; the introduction of Bispectral Index (an EEG parameter) could bring potential advantages in monitoring sedation. According to the reports, Bispectral Index correlates with levels of sedation on the Ramsay Scale. We report our personal experience in this topic. ⋯ The results of the study are consistent with those found in the literature on this topic of study. In fact, this study demonstrates the utility of BIS to track levels of consciousness in ICU patients while still maintaining the use of the score systems to care for ICU patients.
-
J Clin Monit Comput · Jul 2002
Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method.
This work attempts to show how pulmonary blood flow (Qp), cardiac output (CO(Fick)) and the lung volume of effective gas exchange (ELV) can be determined from breath-by-breath measurements of the tidal exhaled CO2 elimination V (litre/min) and the end tidal CO2 concentration P (%) using the differential Fick method. The measurements are made during steady state ventilation and when the CO2 balance in the lungs changes subsequent to a perturbation of the gas exchange conditions. ⋯ With a single breath perturbation, the differential Fick method can yield cardiopulmonary information using 2-3 breaths only and with a minimum of interference with the patient. Complete data analysis results in multiple determinations of the Qp and ELV values which improve the attainable precision. Our investigation points to the possibility to determine Qp, CO(Fick) and ELV also during spontaneous breathing, by using the natural tidal variations of V and P.