Randomized Controlled TrialThe utility of bispectral index monitoring for sedated patients treated with low-dose remifentanil.
The aim of the present study was to determine the effect of low-dose remifentanil on the monitoring quality of the Bispectral index for mechanically ventilated patients. Twelve patients who underwent elective surgery and required mechanical ventilation post-operatively were enrolled in this study with written informed consent. Eligible patients were divided into two groups. ⋯ These values were assessed by single regression analysis and a P value of <0.05 was considered significant. There was a significant correlation between RASS and BIS values (P = 3 × 10(-12), R (2) = 0.67) in the remifentanil group, but not in the control group (P = 0.50, R (2) = 0.057). The administration of low-dose remifentanil makes BIS a more precise tool for sedated patients under mechanical ventilation in the ICU.
-
J Clin Monit Comput · Dec 2012
Randomized Controlled TrialA beat-by-beat, on-line, cardiovascular index, CARDEAN, to assess circulatory responses to surgery: a randomized clinical trial during spine surgery.
Automated assessment of circulatory response to surgical stimuli is unsolved. Would detection of cardiac baroreflex inhibition assess adequacy of intra-operative anti-nociception upon incision, as performed on-line on a beat-by-beat basis by a cardiovascular index, CARDEAN™? 18 ASA I-II patients undergoing spinal disc repair were studied, in a prospective randomized single-blinded trial (observational study). During infusion of propofol to maintain bispectral index between 40 and 60, patients were allocated to receive an effect site target-controlled infusion of remifentanil at Ce = 2 or 4 ng ml(-1). ⋯ Upon skin incision, CARDEAN increased in the remifentanil Ce = 2 ng ml(-1) group (n = 7, P < 0.05), while it did not increase in the remifentanil Ce = 4 ng ml(-1) group (n = 7, P = 0.18). During surgery, retrospectively, CARDEAN > 60 was associated with tachycardia and hypertension (P (k) = 0.81 ± 0.10). Changes in CARDEAN appeared linked to adequacy of anti-nociception.
-
J Clin Monit Comput · Dec 2012
Randomized Controlled TrialValidation of the new intubation detector device: a manikin study.
This study was done to validate the utility of Umesh's intubation detector in detection of tracheal or oesophageal intubation in manikin using volunteers with different levels of experience in tracheal intubation (including novices). The Sim Man II, (Laerdal Medical AS, Norway) manikin was used. Two cuffed tracheal tubes of size 6.5 mm ID were used. ⋯ Out of a total 100 performances, 99 were correctly identified. On one instance, a tube placed in trachea was incorrectly interpreted to be in the oesophagus by a novice. Umesh's intubation detector helps in rapid and reliable confirmation of tracheal intubation in manikin irrespective of the experience level of the assessor in tracheal intubation.