Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2016
Variability of FeNO in healthy subjects at 2240 meters above sea level.
Fraction of exhaled nitric oxide (FeNO) is a marker of eosinophilic airway inflammation. Altitude above sea level can affect measurements of this index, but there is only limited information regarding the diurnal variation (ante meridiem vs. post meridiem) and reproducibility of FeNO on consecutive days at moderate altitudes. To evaluate the diurnal variability of FeNO and assess its reproducibility over five consecutive days in healthy individuals living at 2240 m, and to compare the FeNO readings taken with two different analyzers. ⋯ The CV and CR of the five morning readings were 15.4 % and 4.3 ppb, respectively; while those of the five afternoon measures were 13.6 % and 3.5 ppb, respectively. The CCC between the NIOX MINO(®) equipment and the NOA-280i(®) device was 0.8, with 95 % limits of agreement of -8.35 to 0.29 ppb. In adults living at 2240 m above sea level, FeNO measurements show minimal diurnal variation, and readings are reproducible (<15 %) over a period of at least five consecutive days; however, the FeNO measurements obtained with the NIOX MINO(®) and NOA 280i(®) devices are not interchangeable due to the wide limits of agreement recorded.
-
J Clin Monit Comput · Aug 2016
Observational StudyThe prevalence of long QT interval in post-operative intensive care unit patients.
The severity of patient illnesses and medication complexity in post-operative critically ill patients increase the risk for a prolonged QT interval. We determined the prevalence of prolonged QTc in surgical intensive care unit (SICU) patients. We performed a prospective cross-sectional study over a 15-month period at a major academic center. ⋯ None of the patients developed a lethal arrhythmia in the ICU. Prolonged QTc is common among post-operative SICU patients (67 %), however lethal arrhythmias are uncommon. The operative experience increases the risk for long QTc.
-
J Clin Monit Comput · Aug 2016
Comparative StudyComparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.
A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. ⋯ Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending.
-
J Clin Monit Comput · Aug 2016
Comparative StudyA comparison of different synchronization measures in electroencephalogram during propofol anesthesia.
Electroencephalogram (EEG) synchronization is becoming an essential tool to describe neurophysiological mechanisms of communication between brain regions under general anesthesia. Different synchronization measures have their own properties to reflect the changes of EEG activities during different anesthetic states. However, the performance characteristics and the relations of different synchronization measures in evaluating synchronization changes during propofol-induced anesthesia are not fully elucidated. ⋯ Moreover, PCMI, NI, DET correlated closely with each other and they had a better robustness to noise and higher correlation with BIS and C eff than other synchronization indexes. Propofol caused EEG synchronization changes during the anesthetic period. Different synchronization measures had individual properties in evaluating synchronization changes in different anesthetic states, which might be related to various forms of neural activities and neurophysiological mechanisms under general anesthesia.
-
J Clin Monit Comput · Aug 2016
Randomized Controlled TrialThe effect of low-dose dexmedetomidine on hemodynamics and anesthetic requirement during bis-spectral index-guided total intravenous anesthesia.
The purpose of this study was to evaluate the effects of low-dose dexmedetomidine on hemodynamics and anesthetic requirements during propofol and remifentanil anesthesia for laparoscopic cholecystectomy. Thirty adult patients were randomly allocated to receive dexmedetomidine infusion of 0.3 μg/kg/h (dexmedetomidine group, n = 15) or comparable volumes of saline infusion (control group, n = 15). Target controlled infusion of propofol and remifentanil was used for anesthetic induction and maintenance, and adjusted in order to maintain a bispectral index of 40-55 and hemodynamic stability. ⋯ Significantly lower mean arterial pressure was observed in the dexmedetomidine group than in the control group at immediately and 5 min after pneumoperitoneum. The time to extubation after completion of drug administration did not differ between the groups (P = 0.25). This study demonstrated that a low-dose dexmedetomidine infusion of 0.3 μg/kg/h reduced propofol and remifentanil requirements as well as hemodynamic change by pneumoperitoneum without delayed recovery during propofol-remifentanil anesthesia for laparoscopic cholecystectomy.