A mainstream monitoring system for respiratory CO2 concentration and gasflow.
Continuous respiratory gas monitoring is an important tool for clinical monitoring. In particular, measurement of respiratory [Formula: see text] concentration and gasflow can reflect the status of a patient by providing parameters such as volume of carbon dioxide, end-tidal [Formula: see text] respiratory rate and alveolar deadspace. However, in the majority of previous work, [Formula: see text] concentration and gasflow have been studied separately. ⋯ Statistical analysis using the coefficient of variation was performed to find the optimal driving voltage of the pressure transducer. Calibration between variations and flows was used to avoid pressure signal drift. We carried out targeted experiments using the proposed device and confirmed that the device can produce stable signals.
-
J Clin Monit Comput · Aug 2016
Observational StudyNear-infrared spectroscopy assessed cerebral oxygenation during open abdominal aortic aneurysm repair: relation to end-tidal CO2 tension.
During open abdominal aortic aneurism (AAA) repair cerebral blood flow is challenged. Clamping of the aorta may lead to unintended hyperventilation as metabolism is reduced by perfusion of a smaller part of the body and reperfusion of the aorta releases vasodilatory substances including CO2. We intend to adjust ventilation according end-tidal CO2 tension (EtCO2) and here evaluated to what extent that strategy maintains frontal lobe oxygenation (ScO2) as determined by near infrared spectroscopy. ⋯ Changes in ScO2 related to those in EtCO2 (r = 0.41; P = 0.0001) and cerebral deoxygenation (-15 %) was noted in three patients while cerebral hyperoxygenation (+15 %) manifests in one patient. Thus changes in ScO2 were kept within acceptable limits (±15 %) in 91 % of the patients. For the majority of the patients undergoing AAA repair ScO2 was kept within reasonable limits by reducing ventilation by approximately 1 l min(-1) upon clamping of the aorta and increasing ventilation by approximately 2 l min(-1) when the lower body is reperfused.
-
J Clin Monit Comput · Aug 2016
Safe transcranial electric stimulation motor evoked potential monitoring during posterior spinal fusion in two patients with cochlear implants.
Transcranial electric stimulation (TES) motor evoked potentials (MEPs) have become a regular part of intraoperative neurophysiologic monitoring (IONM) for posterior spinal fusion (PSF) surgery. Almost all of the relative contraindications to TES have come and gone. ⋯ Herein we illustrate two cases of pediatric patients with CIs who underwent PSF using TES MEPs as part of IONM. In both instances the patients displayed no untoward effects from TES, and post-operatively both CIs were intact and functioning as they were prior to surgery.
-
J Clin Monit Comput · Aug 2016
Randomized Controlled TrialThe relationship between the Bispectral Index (BIS) and the Observer Alertness of Sedation Scale (OASS) scores during propofol sedation with and without ketamine: a randomized, double blinded, placebo controlled clinical trial.
Prior studies have examined the static effect of intravenous ketamine on the BIS Index for sedation but it remains unknown if the BIS Index is a reliable method to track sedation levels in the presence of ketamine. The major objective of the current investigation was to compare the BIS Vista Index ability to track varying depths of sedation as determined by OASS scores in a standardized anesthetic regimen with and without ketamine. The study was a randomized, double blinded clinical trial. ⋯ There was no difference in the odds for BIS values to predict deep sedation between groups (P = 0.14). The BIS monitor can be used to monitor sedation level even when ketamine is used with propofol as part of the sedation regimen. However, ketamine reduces the value of the BIS in predicting moderate sedation levels.
-
J Clin Monit Comput · Aug 2016
Comparative StudyContinuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.
The CNAP system (CNSystems Medizintechnik AG, Graz, Austria) provides noninvasive continuous arterial pressure measurements by using the volume clamp method. Recently, an algorithm for the determination of cardiac output by pulse contour analysis of the arterial waveform recorded with the CNAP system became available. We evaluated the agreement of the continuous noninvasive cardiac output (CNCO) measurements by CNAP in comparison with cardiac output measurements invasively obtained using transpulmonary thermodilution (TDCO). ⋯ This pilot analysis shows that CNCO determination is feasible in critically ill patients. A percentage error of 25 % indicates acceptable agreement between CNCO-cal and TDCO. The mean difference, the standard deviation, and the percentage error between CNCO-auto and TDCO were higher than between CNCO-cal and TDCO. A hyperdynamic cardiocirculatory state in a substantial number of patients and the hemodynamic stability making trending analysis impossible are main limitations of our study.