Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2017
Impact of microcirculatory video quality on the evaluation of sublingual microcirculation in critically ill patients.
We aimed to assess the impact of image quality on microcirculatory evaluation with sidestream dark-field (SDF) videomicroscopy in critically ill patients and explore factors associated with low video quality. This was a retrospective analysis of a single-centre prospective observational study. Videos of the sublingual microcirculation were recorded using SDF videomicroscopy in 100 adult patients within 12 h from admittance to the intensive care unit and every 24 h until discharge/death. ⋯ Perfused vessel density was higher in patients with Glasgow Coma Scale (GCS) ≤8 (18.9 ± 4.5 vs. 17.0 ± 3.9 mm/mm2 in those with GCS >8, p < 0.001) or requiring mechanical ventilation (18.0 ± 4.5 vs. 17.2 ± 3.8 mm/mm2 in not mechanically ventilated patients, p = 0.059). We concluded that SDF video quality depends on both the operator's experience and patient's cooperation. Low-quality videos may produce spurious data, leading to an overestimation of microvascular alterations.
-
J Clin Monit Comput · Oct 2017
Identifying the position of the right atrium to align pressure transducer for CVP : Spirit level or 3D electromagnetic positioning?
The central venous pressure, CVP, is an important variable in the management of selected perioperative and intensive care cases and in clinical decision support systems, CDSS. In current routine, when measuring CVP the health care provider may use anatomical landmarks and a spirit level, SL, to adjust the pressure transducer to the level of the tricuspid valve, i.e. the phlebostatic axis. The aim of the study was to assess the agreement in the postoperative setting between the SL method and electromagnetic 3D positioning (EM). ⋯ The limits of agreement extended in excess of ±8 mmHg and half of the measurements had deviations outside an accepted error range of ±2.5 mmHg. There was a large variation in CVP measurements when assessing the agreement with the current method. This may indicate the need for improvement in accuracy, e.g. using the electromagnetic field positioning system, in association with routine monitoring and clinical decision support systems.
-
J Clin Monit Comput · Oct 2017
Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor.
Alterations in arterial blood oxygen saturation, heart rate (HR), and respiratory rate (RR) are strongly associated with intra-hospital cardiac arrests and resuscitations. A wireless, easy-to-use, and comfortable method for monitoring these important clinical signs would be highly useful. We investigated whether the Nellcor™ OxiMask MAX-FAST forehead sensor could provide data for vital sign measurements when located at the distal forearm instead of its intended location at the forehead to provide improved comfortability and easy placement. ⋯ For HR measurements, the mean difference was 0.6 bpm (SD, 2.5), r = 0.997, and RMSE = 1.8. For RR, the mean difference was -0.5 1/min (4.1), r = 0.586, and RMSE = 4.0. The SpO2 readings showed a low mean difference, but also a low correlation and high RMSE, indicating that the Nellcor™ saturation sensor cannot reliably assess oxygen saturation at the forearm when compared to finger PPG measurements.
-
J Clin Monit Comput · Oct 2017
Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia.
The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. ⋯ No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW.
-
J Clin Monit Comput · Oct 2017
Efficacy and safety of novel high-frequency multi-train stimulation for recording transcranial motor evoked potentials in a rat model.
Recently, low-frequency multi-train stimulation (MTS) was shown to effectively enhance transcranial motor-evoked potentials (TcMEPs). In contrast, high- frequency double-train stimulation was reported to elicit a marked facilitation. The aim of this study was to evaluate the efficacy of high-frequency MTS in the augmentation of potentials. ⋯ The aversion index was >0.8 in all animals after they received 100 high-frequency MTSs. Histologically, no pathological changes were evident in the rat brains. High-frequency MTS shows potential to effectively enhance TcMEP responses, and to be used safely in transcranial brain stimulation.