Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients.
The Masimo Radical-7 Pulse CO-Oximeter (Masimo Corp., USA) non-invasively computes hemoglobin concentration (SpHb). SpHb was compared to Co-Oximeter readings (CoOxHb) of arterial samples in surgery patients of the emergency department. Forty-six patients were enrolled. ⋯ SpHb agreed only moderately with CoOxHb values and predicted decreases of CoOxHb only if changes of SpHb ≤ 1.0 g/dl were excluded. The detection failure rate of SpHb was high. At present, additional refinements of the current technology are necessary to further improve performance of non-invasive hemoglobin measurement in the clinical setting.
-
J Clin Monit Comput · Feb 2017
Effect of wearing an N95 filtering facepiece respirator on superomedial orbital infrared indirect brain temperature measurements.
To determine any effect of wearing a filtering facepiece respirator on brain temperature. Subjects (n = 18) wore a filtering facepiece respirator (FFR) for 1 h at rest while undergoing infrared thermography measurements of the superomedial periobital region of the eye, a non-invasive indirect method of brain temperature measurements we termed the superomedial orbital infrared indirect brain temperature (SOIIBT) measurement. Temperature of the facial skin covered by the FFR, infrared temperature measurements of the tympanic membrane and superficial temporal artery region were concurrently measured, and subjective impressions of thermal comfort obtained simultaneously. ⋯ The SOIIBT values did not change significantly, but subjects who switched from nasal to oronasal breathing during the study (n = 5) experienced a slight increase in the SOIIBT measurements. Wearing a FFR for 1 h at rest does not have a significant effect on brain temperatures, as evaluated by the SOIIBT measurements, but a change in the route of breathing may impact these measurements. These findings suggest that subjective impressions of thermal discomfort from wearing a FFR under the study conditions are more likely the result of local dermal sensations rather than brain warming.
-
J Clin Monit Comput · Feb 2017
A systematic database-derived approach to improve indexation of transpulmonary thermodilution-derived global end-diastolic volume.
Global end-diastolic volume (GEDV) has been indexed to body surface area (BSA). However, data validating this indexation of GEDV are scarce. Furthermore, it has been suggested to index GEDV to "predicted BSA" based on predicted body weight. ⋯ GEDV was independently associated with older age, male sex, height, and actual body weight. In a regression model for the estimation of GEDV, age and height were the most important parameters: Each year in age and each cm in height increased GEDV by 9 and 15 mL, respectively. In addition to height and weight also age and sex should be considered for indexation of GEDV.
-
J Clin Monit Comput · Feb 2017
Randomized Controlled Trial Comparative StudyComparison of intraoperative volume and pressure-controlled ventilation modes in patients who undergo open heart surgery.
Respiratory problems occur more frequently in patients who undergo open heart surgery. Intraoperative and postoperative ventilation strategies can prevent these complications and reduce mortality. We hypothesized that PCV would have better effects on gas exchange, lung mechanics and hemodynamics compared to VCV in CABG surgery. ⋯ The hemodynamic effects of both ventilation modes were found to be similar. PVC may be preferable to VCV in patients who undergo open heart surgery. However, it would be convenient if our findings are supported by similar studies.