Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jun 2020
Review Meta AnalysisAccuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.
Cardiac output monitoring is used in critically ill and high-risk surgical patients. Intermittent pulmonary artery thermodilution and transpulmonary thermodilution, considered the gold standard, are invasive and linked to complications. Therefore, many non-invasive cardiac output devices have been developed and studied. ⋯ Despite the low bias for both adults and pediatrics, the MPE was not clinically acceptable. Electrical cardiometry cannot replace thermodilution and transthoracic echocardiography for the measurement of absolute cardiac output values. Future research should explore it's clinical use and indications.
-
J Clin Monit Comput · Jun 2020
Multicenter Study Observational StudyCharacterization of respiratory compromise and the potential clinical utility of capnography in the post-anesthesia care unit: a blinded observational trial.
The utility of capnography to detect early respiratory compromise in surgical patients after anesthesia is unclear due to limited prospective data. The purpose of this trial was to determine the frequency and duration of capnography-detected respiratory adverse events in the post-anesthesia care unit (PACU). In this prospective observational trial, 250 consenting patients undergoing elective surgery with general anesthesia were monitored by standard monitoring together with blinded capnography and pulse oximetry monitoring. ⋯ Three patients' blinded capnography was unblinded to facilitate clinical care. Respiratory adverse events are frequent in the PACU, and the addition of capnography and IPI to current standard monitoring provides potentially clinically relevant information on respiratory status, including early warning of some respiratory adverse events. Trial registration ClinialTrials.gov Identifier NCT02707003 (https://clinicaltrials.gov/ct2/show/NCT02707003).
-
J Clin Monit Comput · Jun 2020
Comparative StudyThe value of a superior vena cava collapsibility index measured with a miniaturized transoesophageal monoplane continuous echocardiography probe to predict fluid responsiveness compared to stroke volume variations in open major vascular surgery: a prospective cohort study.
Superior vena cava collapsibility index (SVC-CI) and stroke volume variation (SVV) have been shown to predict fluid responsiveness. SVC-CI has been validated only with conventional transoesophageal echocardiography (TEE) in the SVC long axis, on the basis of SVC diameter variations, but not in the SVC short axis or by SVC area variations. SVV was not previously tested in vascular surgery patients. ⋯ Our study validated the value of the SVC-CI measured as area variations in the SVC short axis to predict fluid responsiveness in anesthetized patients. An hTEE probe was used to monitor and measure the hSVC-CI but conventional TEE may also offer this new dynamic parameter. In our cohort of significant preoperative hypovolemic patients undergoing major open vascular surgery, hSVC-CI and SVV cutoff values of 37% and 15%, respectively, predicted fluid responsiveness with good accuracy.
-
J Clin Monit Comput · Jun 2020
ReviewJournal of Clinical Monitoring and Computing 2019 end of year summary: monitoring tissue oxygenation and perfusion and its autoregulation.
Tissue perfusion monitoring is increasingly being employed clinically in a non-invasive fashion. In this end-of-year summary of the Journal of Clinical Monitoring and Computing, we take a closer look at the papers published recently on this subject in the journal. ⋯ Given the importance of cerebral autoregulation in the analyses performed in most of the studies discussed here, this end-of-year summary also includes a short description of cerebral hemodynamic physiology and its autoregulation. Finally, we review articles on somatic tissue oxygenation and its possible association with outcome.
-
J Clin Monit Comput · Jun 2020
Clinical TrialAdjustment of oxygen reserve index (ORi™) to avoid excessive hyperoxia during general anesthesia.
The Oxygen Reserve Index (ORi™) is a non-invasive variable that reflects oxygenation continuously. The aims of this study were to examine the relationship between arterial partial pressure of oxygen (PaO2) and ORi during general anesthesia, and to investigate the usefulness of ORi as an indicator to avoid hyperoxia. Twenty adult patients who were scheduled for surgery under general anesthesia with arterial catheterization were enrolled. ⋯ The cut-off ORi value obtained from the receiver operating characteristic curve to detect PaO2 ≥ 150 mmHg was 0.21 (sensitivity 0.950, specificity 0.755). Four-quadrant plot analysis showed that the ORi trending of PaO2 was good (concordance rate was 100.0%). Hyperoxemia can be detected by observing ORi of patients under general anesthesia, and thus unnecessary administration of high concentration oxygen can possibly be avoided.