Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2020
Ultrasonographic measurement of the ligamentum flavum at different angles in the lateral tilt position.
The aim of this study was to take ultrasonographic measurements of the length of the ligamentum flavum (LF), the LF-skin distance and the interspinous distance, which are critical for the application of neuraxial anaesthesia, with volunteers in the sitting position and with lateral tilt of the operating table at different angles to evaluate whether the target structures in neuraxial anaesthesia can be better visualised with the lateral tilt position and to determine whether or not these measurements change at different angles. The study included 29 volunteers. For the measurements, the operation table was first set into the neutral position and the length of the LF, the skin-LF distance and the interlaminar distance were measured at between L1-S1 spaces with a paramedian oblique sagittal approach with a linear ultrasound probe. ⋯ In the ultrasonographic measurements of the skin-LF distance, at L3-4 and L4-5 intervertebral interspaces, there was a statistically significant increase. With lateral tilt applied to the table, there was determined to be an increase in ultrasonographic measurements of the LF length in the lumbar intervertebral interspaces. Therefore, for neuraxial blocks applied in the sitting position, the procedure may be facilitated with lateral tilt of the operating table.
-
J Clin Monit Comput · Jun 2020
Clinical Trial Observational StudyPrediction of postoperative pain and analgesic requirements using surgical pleth index: a observational study.
The aim of this study was to evaluate the performance of surgical pleth index (SPI) measured before arousal from general anaesthesia for prediction of immediate postoperative pain and postoperative opioid requirement during postoperative 48 h. After obtaining ethical approval and written informed consent, we enrolled 51 patients undergoing liver resection under isoflurane based general anaesthesia using laryngeal mask airway in this prospective observational study. Data relating to SPI values were recorded every 30 s for the last 3 min of surgery (bispectral index < 60 at all times). ⋯ When compared the patients who showed SPI value over 60 or not, there was significant difference in the amount of fentanyl consumption during postoperative 48 h (1093 ± 406 µg vs. 766 ± 369 µg, p = 0.014; SPI ≥ 60 vs. SPI < 60). SPI measured before arousal after inhalation anaesthesia was associated with immediate postoperative pain and postoperative opioid consumption.
-
J Clin Monit Comput · Jun 2020
Optimizing the use of point of care testing devices for screening patients.
Point of Care Testing (POCT) devices are regularly used to improve clinical workflows in the hospital setting despite generally having inferior performance when compared to standardized laboratory analyzers. We describe a method to improve the efficacy of using a POCT device as a screening test when the laboratory values occur over a continuum and applied this methodology to the process of International Normalized Ratios (INR) screening on day of surgery. Following IRB approval, laboratory INR values on the day of surgery were extracted from the University of Vermont Medical Center operating room's electronic health record. ⋯ The sensitivities and specificities over a range of values were determined, and the optimal cutoff values were identified for each device separately. Calculating the sensitivities and specificities over a range of values can optimize the clinical efficacy of a POCT device. By optimizing the use of POCT devices, hospitals may be able to improve clinical processes and reduce costs.
-
J Clin Monit Comput · Jun 2020
Clinical TrialUse of a novel non-invasive respiratory monitor to study changes in pulmonary ventilation during labor epidural analgesia.
Measuring continuous changes in maternal ventilation during labor neuraxial analgesia is technically difficult. Consequently, the magnitude of pulmonary minute ventilation (MV) alterations following labor analgesia remains unknown. We hypothesized that a novel, bio-impedance based non-invasive respiratory monitor would provide this information. ⋯ Our findings suggest that RVM can be a useful noninvasive technology to investigate pulmonary physiology during labor. The association between maternal MV and temperature change during labor analgesia deserves further investigation. Trial Registrationwww.clinicaltrials.gov (NCT02339389).