Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2023
Reliability and reproducibility of the DICART device to assess capillary refill time: a bench and in-silico study.
Capillary refill time (CRT) is an important indicator of peripheral perfusion with a strong prognostic value, but it is sensitive to environmental factors and numerous measurement methods are reported in the litterature. DiCARTECH has developed a device that assesses CRT. We sought to investigate the robustness of the device and the reproducibility of the algorithm in a bench and in-silico study. ⋯ For the color-jitter modified video the coefficient of variation was 62% (95%CI: 55-70). We confirmed the ability of the DiCART™ II device to perform multiple measurements without mechanical or electronic dysfunction. The precision and reproducibility of the algorithm are compatible with the assessment of clinical small changes in CRT.
-
J Clin Monit Comput · Feb 2024
Randomized Controlled TrialEffect of paratracheal pressure on the effectiveness of mask ventilation in obese anesthetized patients: a randomized, cross-over study.
Paratracheal pressure has been recently suggested to compress and occlude the upper esophagus at the lower left paratracheal region to prevent gastric regurgitation alternative to cricoid pressure. It also prevents gastric insufflation. The aim of this randomized cross-over study was to investigate the effectiveness of paratracheal pressure on mask ventilation in obese anesthetized paralyzed patients. ⋯ Hypoxemia did not occur in any of the patients during mask ventilation with or without paratracheal pressure. The application of paratracheal pressure significantly increased both the expiratory tidal volume and peak inspiratory pressure during face-mask ventilation with a volume-controlled mode in obese anesthetized paralyzed patients. Gastric insufflation was not evaluated in this study during mask ventilation with or without paratracheal pressure.
-
J Clin Monit Comput · Oct 2023
Clinical validation of an adapted Eleveld Model for high-dose propofol treatments for depression.
Repeated administration of high doses of propofol to patients with treatment-resistant depression (TRD) has been shown to produce antidepressant effects in small clinical trials. These effects can be elicited when the patient's EEG burst-suppression ratio (BSR) is maintained at 70-90% for 15 min in repeated treatments. This deep anesthesia domain lies beyond the range of current propofol pharmacokinetic/pharmacodynamic (PK/PD) models. ⋯ Median absolute performance error (MdAPE) between the estimated and observed BSR (25th-75th percentile) was 6.63 (3.79-12.96) % points and 8.51 (4.32-16.74) % between the estimated and observed treatment duration. This predictive performance is statistically significantly better at predicting BSR compared with the standard Eleveld model at deep anesthesia levels. Our adapted Eleveld model provides a useful tool to aid dosing propofol for high-dose anesthetic treatments for depression.
-
J Clin Monit Comput · Feb 2024
ReviewIntraoperative haemodynamic monitoring and management of adults having non-cardiac surgery: Guidelines of the German Society of Anaesthesiology and Intensive Care Medicine in collaboration with the German Association of the Scientific Medical Societies.
Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).
-
J Clin Monit Comput · Oct 2023
Case ReportsNoninvasive neuromonitoring with rheoencephalography: a case report.
Cerebral blood flow (CBF) autoregulation (AR) can be monitored using invasive modalities, such as intracranial pressure (ICP) and arterial blood pressure (ABP) to calculate the CBF AR index (PRx). Monitoring PRx can reduce the extent of secondary brain damage in patients. Rheoencephalography (REG) is an FDA-approved non-invasive method to measure CBF. ⋯ REG pulse wave morphology changed from poor ICC to good ICC morphology. Bioimpedance recording made it possible to quantify the active/passive status of CBF AR, indicate the worsening of ICC, and present it in real time. REGx can be a suitable, non-invasive alternative to PRx for use in head-injured patients.