Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2023
ReviewBioelectrical impedance analysis during deresuscitation: correlation and agreement with cumulative fluid balance in ICU patients.
Bioelectrical impedance analysis (BIA) is a promising tool to evaluate the body composition of critically-ill patients. The present study aimed to assess its value as a fluid management monitoring tool during standardized deresuscitation strategy. A historical cohort of critically-ill adult patients with fluid overload and continuous renal replacement therapy was used to explore both relationship and agreement between changes in cumulative fluid balance and BIA-derived hydration variables within the 5 days following initiation of deresuscitation strategy using net ultrafiltration. ⋯ Total body water (rho = 0.63), extracellular water (rho = 0.68), and intracellular water (rho = 0.67) were significantly correlated with cumulative fluid balance (all P values < 0.001). The limits of agreement did not allow interchangeability for a delta of 2L between cumulative fluid balance and BIA-derived hydration variables (P > 0.05). BIA hydration-derived variables are significantly correlated with cumulative fluid balance but the large limits of agreements exclude interchangeability of the measures.
-
J Clin Monit Comput · Apr 2023
ReviewUltrasound-guided cerebral resuscitation in patients with severe traumatic brain Injury.
Traumatic brain injury (TBI) is a worldwide public health concern given its significant morbidity and mortality, years of potential life lost, reduced quality of life and elevated healthcare costs. The primary injury occurs at the moment of impact, but secondary injuries might develop as a result of brain hemodynamic abnormalities, hypoxia, and hypotension. The cerebral edema and hemorrhage of the injured tissues causes a decrease in cerebral perfusion pressure (CPP), which leads to higher risk of cerebral ischemia, herniation and death. ⋯ Performing a transcranial doppler ultrasound (TCD) allows to estimate cerebral blood flow velocities and identify states of low flow and high resistance. We propose to include TCD as an initial assessment and further monitoring tool for resuscitation guidance in patients with severe TBI. We present an Ultrasound-Guided Cardio-cerebral Resuscitation (UGCeR) protocol in Patients with Severe TBI.
-
J Clin Monit Comput · Apr 2023
ReviewReliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review.
The reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. ⋯ The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.
-
J Clin Monit Comput · Apr 2023
ReviewReliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review.
The reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. ⋯ The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.
-
J Clin Monit Comput · Feb 2023
ReviewThe impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence.
Novel technologies allow continuous wireless monitoring systems (CWMS) to measure vital signs and these systems might be favorable compared to intermittent monitoring regarding improving outcomes. However, device safety needs to be validated because uncertain evidence challenges the clinical implementation of CWMS. This review investigates the frequency of device-related adverse events in patients monitored with CWMS in general hospital wards. ⋯ The studies of the SensiumVitals® patch, the iThermonitor, and the ViSi Mobile® device reported 28 (9%), 25 (5%), and 1 (3%) ADEs, respectively. No ADEs were reported using the HealthPatch, WARD 24/7 system, or Coviden Alarm Management. Current evidence suggests that CWMS are safe to use but systematic reporting of all adverse device effects is warranted.