Adv Exp Med Biol
-
Automatically stepwise driven pO2 electrodes were transcutaneously inserted into muscle tissue of severely ill septic shock patients. The pO2 profile was plotted from 200 individual measurements registered during 5 minutes and a histogram plotted for documentation. Arterial and venous blood gases, cardiac output, systemic and pulmonary vascular resistance were measured continuously on-line. ⋯ The investigations show that resulting changes of cardiovascular and blood gas parameters do not always indicate that tissue oxygen supply has really improved. On the other hand there was never an improvement in tissue oxygen supply when no changes of the other parameters had occurred. It is advised to add as a further diagnostic parameter tissue pO2 measurements to get insight if improvement in cardiac and pulmonary function really has the intended effect of improvement of tissue oxygen supply.
-
Comparative Study Clinical Trial
Evaluation of oxygenation with different modes of ventilation in patients with adult respiratory distress syndrome.