LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study.
Occurrence of adverse effects and advantages of the LigaSure diathermy system (or LigaSure vessel sealing system) in total thyroidectomy have not been tested in prospective randomized studies comparing its use with that of the time-saving clamp-and-tie technique to ligate and divide thyroid vessels. The effectiveness of LigaSure in achieving vessel division and hemostasis remains dependent on vessel diameter, and the risk of damage to adjacent structures cannot be completely excluded. We tested the hypothesis that use of LigaSure compared with the clamp-and-tie technique can significantly and conveniently reduce operative time without increasing postoperative complications in patients undergoing total thyroidectomy for benign multinodular goiter. ⋯ The use of LigaSure is equally as safe and effective at vessel division and homeostasis as the clamp-and-tie technique, with a statistically significant (although minimal) decrease in mean operative time. Because of this minimal decrease in operative time, use of LigaSure would allow more patients to undergo total thyroidectomy each year, which would eventually help to offset its higher cost.