Neurosurg Focus
-
OBJECTIVE The accuracy of robot-guided pedicle screw placement has been proven to be high, but little is known about the impact of such guidance on clinical outcomes such as the rate of revision surgeries for screw malposition. In addition, there are very few data about the impact of robot-guided fusion on patient-reported outcomes (PROs). Thus, the clinical benefit for the patient is unclear. ⋯ Ability to work increased from 38.9% to 78.2% of patients (p < 0.001) at the final follow-up, and 89.1% of patients indicated they would choose to undergo the same treatment again. CONCLUSIONS In adults with low-grade spondylolisthesis, the data demonstrated a benefit in using robotic guidance to reduce the rate of revision surgery for screw malposition as compared with other techniques of pedicle screw insertion described in peer-reviewed publications. Larger comparative studies are required to assess differences in PROs following a minimally invasive approach in spinal fusion surgeries compared with other techniques.
-
OBJECTIVE Surgical robotics has demonstrated utility across the spectrum of surgery. Robotics in spine surgery, however, remains in its infancy. Here, the authors systematically review the evidence behind robotic applications in spinal instrumentation. ⋯ CONCLUSIONS Robotics in spine surgery is an emerging technology that holds promise for future applications. Surgical accuracy in instrumentation implanted using robotics appears to be high. However, the impact of robotics on radiation exposure is not clear and seems to be dependent on technique and robot type.
-
Objective Age and lesion level are believed to represent outcome predictors in rehabilitation of patients with chronic spinal cord injury (SCI). The Hybrid Assistive Limb (HAL) exoskeleton enables patients to perform a voluntary controlled gait pattern via an electromyography-triggered neuromuscular feedback system, and has been introduced as a temporary gait training tool in patients with SCI. The aim of this prospective pre- and postintervention study was to examine functional outcomes as a function of age and lesion level in patients with chronic incomplete SCI (iSCI) or chronic complete SCI (cSCI) with zones of partial preservation (ZPP) by using the HAL as a temporary training tool. ⋯ Older age (≥ 50 years) may be associated with smaller improvements in the 10MWTsss. An iSCI in paraplegic patients with spastic motor behavior may be a nonsignificant negative predictor in gait endurance improvements. Clinical trial registration no.: DRKS00010250 ( https://drks-neu.uniklinik-freiburg.de/drks_web/setLocale_DE.do ).
-
Comparative Study
Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
OBJECTIVE Robot-guided pedicle screw placement is an established technique for the placement of pedicle screws. However, most studies have focused on degenerative disease. In this paper, the authors focus on metastatic spinal disease, which is associated with osteolysis. ⋯ There was also no difference in radiation time between the groups (Group I, 138.2 ± 73.0 seconds; Group II, 126.5 ± 95.6 seconds; p = 0.61), but the radiation intensity was higher in the robot group (Group I, 2.8 ± 0.2 mAs; Group II, 2.0 ± 0.6 mAs; p < 0.01). CONCLUSIONS Pedicle screw placement for metastatic disease in the thoracolumbar spine can be performed effectively and safely using robot-guided assistance. Based on this retrospective analysis, accuracy, radiation time, and postoperative infection rates are comparable to those of the conventional technique.
-
Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. ⋯ There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.