Minerva anestesiologica
-
Minerva anestesiologica · Mar 1999
Randomized Controlled Trial Clinical Trial[Endotracheal tube cuff pressure. Monitoring during general anesthesia].
To value changes of endotracheal tube cuff pressure during anaesthesia with N2O, using standard tubes or Brandt-system tubes. ⋯ Brandt's double cuff-tubes (G2) succeed in avoiding uncontrolled increase of cuff-pressure during anaesthesia with N2O. Standard low-pressure tubes (G1) shown increase of cuff pressure during anaesthesia with N2O which is absent using no N2O (G3).