World Neurosurg
-
Crossing a nascently deployed carotid artery stent (CAS) is required to perform angioplasty and filter recapture. If the traversing balloon or filter recapture catheters are eccentric or tangentially angled to the vertical axis of the CAS, they can ensnare on the ledge of the proximal CAS step-off, potentially causing life-threatening complications secondary to deformation, displacement, or mechanical occlusion of the stent. We report a novel "balloon bridge" technique that facilitates safe entry and passage across the CAS with both a balloon catheter and a large-bore guide catheter (LBGC). ⋯ Traversing a CAS with an LBGC or balloon catheter can be tedious and fraught with the potential of neurologic peril should mechanical deformation and occlusion occur. The balloon bridge technique is safe and highly effective for navigating a catheter that is eccentric or tangentially angled to the long axis of a CAS.
-
Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. ⋯ An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress.
-
To investigate the relationship between single nucleotide polymorphisms or haplotypes of COL4A1 gene and the outcome of intracerebral hemorrhage (ICH). ⋯ Our study found that the rs532625 AA genotype in the COL4A1 gene was independently associated with the risk of disability at 3 and 6 months and death/disability at 6 months in a Chinese Han population. These conclusions need to be verified in future studies with larger samples.
-
To assess the mid-long-term follow-up of the safety and efficacy of anterior cervical discectomy and fusion (ACDF), cervical artificial disc replacement (CADR) and hybrid surgery (HS) for bilevel cervical degenerative disc disease (cDDD). ⋯ HS was superior to ACDF with regard to equivalent clinical outcomes in the mid-long-term follow-up. Furthermore, HS was superior in the maintenance of ROM and had less impact on its adjacent segments. The efficacy of HS is similar to that of CADR.
-
Clinical Trial
Utility of 3-Dimensional-Printed Models in Enhancing the Learning Curve of Surgery of Tuberculum Sellae Meningioma.
To investigate the value of 3-dimensional (3D)-printed models with pathologic entities in enhancing the learning curve of surgery of tuberculum sellae meningioma. ⋯ 3D-printed models can assist in improving the learning curve of surgery of tuberculum sellae meningiomas. It particularly aids in memorization and spatial construction, improves understanding of surgical view, and arouses interest on the part of the trainee. We recommend using it in the education of complex skull base surgery.