The Journal of thoracic and cardiovascular surgery
-
J. Thorac. Cardiovasc. Surg. · Feb 2023
Multicenter Study Observational StudyBiological versus mechanical prostheses for aortic valve replacement.
Long-term real-world outcomes are critical for informing decisions about biological (Bio) or mechanical (Mech) prostheses for aortic valve replacement, particularly in patients aged between 50 and 65 years. The objective was to compare long-term survival and major adverse cardiac and cardiovascular events (ie, stroke, reoperation, and major bleeding) within this population. ⋯ Long-term survival was comparable among groups in patients between 50 and 65 years of age. Mech prostheses were associated with a higher risk of major bleeding, whereas Bio prostheses entailed higher reoperation rates. Bio prostheses seem a reasonable choice for patients between 50 and 65 years in Spain.