Diving Hyperb Med
-
Scrubbers in closed-circuit rebreather systems remove carbon dioxide (CO2) from the exhaled gas. In an attempt to be more user-friendly and efficient, the ExtendAir® non-granular, pre-formed scrubber cartridge has been developed. The cartridge manufacturer claims twice the absorptive capacity of granular CO2 absorbent, with less variability, lower work of breathing, and reduced exposure to caustic chemicals after a flood. To our knowledge there are no published data that support these claims. ⋯ Cartridge and granular scrubbers were very similar in duration, variability, ventilation pressures, and causticity after a flood. Our findings were not consistent with claims of substantial superiority for the ExtendAir® cartridge.
-
Mesenteric ischaemia results from a lack of adequate blood flow to and oxygenation of the mesentery and intestines. The aim of the present study was to evaluate the effect of hyperbaric oxygen treatment (HBOT) on the healing process in intestinal mucosa of rats undergoing mesenteric ischaemia and reperfusion. ⋯ A beneficial effect of HBOT was observed on oxidative stress and inflammation in acute mesenteric ischaemia-reperfusion.