Resp Care
-
This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor. ⋯ The intra-individual variation of CLT immediately post-intubation and pre-extubation does not improve the accuracy of a standard pre-extubation CLT to predict post-extubation stridor. Moreover, the standard pre-extubation CLT did not appear in our study to be an ideal test to detect post-extubation stridor. Larger studies should be performed before generalizing these preliminary results.
-
To determine the utility of soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) levels in bronchoalveolar lavage fluid (BALF) and exhaled breath condensate (EBC) samples from patients who underwent bronchoscopy for a clinical suspicion of ventilator-associated pneumonia (VAP), to categorize patients as VAP positive and VAP negative, when compared to quantitative culture results of BALF. ⋯ EBC and BALF sTREM-1 levels did not effectively categorize patients as VAP positive or VAP negative when using direct bronchoscopic quantitative culture samples as the comparison standard.
-
The accuracy of end-expiratory lung volume measurement by the modified nitrogen wash-out/wash-in method (EELV-N(2)) depends on the precise determination of carbon dioxide elimination (V(CO(2))), which is affected by alveolar dead space (V(D-alv)). The purpose of this study was to investigate the influence of V(D-alv) on EELV-N(2). ⋯ In this surfactant-depleted model, EELV measurement by the modified EELV-N(2) method reveals a systematic underestimation at high PEEP levels that is partly due to an increase in V(D-alv).
-
Case Reports
Prolonged high-frequency oscillatory ventilation in tubercular multifocal cystic lung disease.
Multifocal cystic lung disease in infants is most commonly congenital, and is managed surgically with perioperative mechanical ventilation. Multifocal cystic lung disease in infants may be due to tuberculosis. We report a young infant with tubercular multifocal cystic lung disease and respiratory failure. ⋯ Subsequent chest imaging showed progression to multifocal cystic lung disease. The ventilation mode was changed to high-frequency oscillatory ventilation (HFOV) due to persistent CO(2) retention in the presence of cystic lung disease. The cystic lung disease reversed with antitubercular treatment and prolonged HFOV with slow wean.
-
Multicenter Study
Adherence to acceptability and repeatability criteria for spirometry in complex lung function laboratories.
Few published data exist for adherence rates to spirometry acceptability and repeatability criteria in clinical respiratory laboratories. This study quantified adherence levels in this setting and observed changes in adherence levels as a result of feedback and ongoing training. ⋯ Clinical respiratory laboratories met published spirometry acceptability and repeatability criteria only 60% of the time in the first audit period. This improved with regular review, feedback, and implementation of a rating scale. Auditing of spirometry quality, feedback, and implementation of test rating scales need to be incorporated as an integral component of laboratory quality assurance programs to improve adherence to international acceptability and repeatability criteria.