Randomized Controlled TrialTreatment of thoracolumbar vertebrate fracture by transpedicular morselized bone grafting in vertebrae for spinal fusion and pedicle screw fixation.
To enhance the fusion of graft bone in thoracolumbar vertebrae and minimize the postoperative loss of correction, short-segment pedicle screw fixation was reinforced with posterior morselized bone grafting in vertebrae for spinal fusion in patients with thoracolumbar vertebrate fractures. Seventy patients with thoracolumbar vertebrate fractures were treated by short-segment pedicle screw fixation and were randomly divided into two groups. Fractures in group A (n=20) were reinforced with posterior morselized bone grafting in vertebrae for spinal fusion, while patients group B (n=50) did not receive the morselized bone grafting for bone fusion. ⋯ By Frankel criteria, the changes in neurological functions in group A was better than those of group B (P<0.001). It is concluded that reinforcement of short-segment pedicle fixation with morselized bone grafting for the treatment of patients with thoracolumbar vertebrae fracture could achieve and maintain kyphosis correction, and it may also increase and maintain anterior vertebral height. Morselized bone grafting in vertebrae offers immediate spinal stability in patients with thoracolumbar vertebrate fractures, decreases the instrument failure and provides better postoperative pain control than without the morselized bone grafting.
-
J Huazhong U Sci Med · Jun 2008
The anatomic study on replacement of artificial atlanto-odontoid joint through transoral approach.
In order to provide anatomical basis for transoral approach (TOA) in dealing with the ventro lesions of craniocervical junction, and the design and application of artificial atlanto-odontoid joint, microsurgical dissecting was performed on 8 fresh craniocervical specimens layer by layer through transoropharyngeal approach. The stratification of posterior pharyngeal wall, course of vertebral artery, adjacent relationship of atlas and axis and correlative anatomical parameters of replacement of artificial atlanto-odontoid joint were observed. Besides, 32 sets of atlanto-axial joint in adults' fresh bony specimens were measured with a digital caliper and a goniometer, including the width of bony window of anterior arch of atlas, the width of bony window of axis vertebra, the distance between superior and inferior two atlas screw inserting points, the distance between two axis screw inserting points etc. ⋯ This study revealed that it had the advantages of short operative distance, good exposure and sufficient decompression in dealing with the ventro lesions from the upper cervical to the lower clivus through the TOA. The replacement of artificial atlanto-odontoid joint is suitable and feasible. The design of artificial atlanto-odontoid joint should be based on the above data.