Minerva medica
-
Contrast media used in mechanical therapies for stroke and myocardial infarction represent a significant cause of acute kidney injury (AKI) in acute medical scenarios. Although the continuous saline infusion line (CSIL) is a standard procedure to prevent thrombus formation within the catheter during neurovascular interventions of mechanical thrombectomy (MT), it is not utilized in percutaneous coronary interventions (PCI). ⋯ Implementation of CSIL during endovascular procedures in acute settings was associated with a significant decrease in the risk of AKI, and its safety should be routinely considered in such interventions.