Cochrane Db Syst Rev
-
Cochrane Db Syst Rev · Jan 2015
Review Meta AnalysisBlood pressure control for diabetic retinopathy.
Diabetic retinopathy is a common complication of diabetes and a leading cause of visual impairment and blindness. Research has established the importance of blood glucose control to prevent development and progression of the ocular complications of diabetes. Simultaneous blood pressure control has been advocated for the same purpose, but findings reported from individual studies have supported varying conclusions regarding the ocular benefit of interventions on blood pressure. ⋯ Hypertension is a well-known risk factor for several chronic conditions in which lowering blood pressure has proven to be beneficial. The available evidence supports a beneficial effect of intervention to reduce blood pressure with respect to preventing diabetic retinopathy for up to 4 to 5 years. However, the lack of evidence to support such intervention to slow progression of diabetic retinopathy or to prevent other outcomes considered in this review, along with the relatively modest support for the beneficial effect on incidence, weakens the conclusion regarding an overall benefit of intervening on blood pressure solely to prevent diabetic retinopathy.
-
Cochrane Db Syst Rev · Jan 2015
Review Meta AnalysisBlood pressure control for diabetic retinopathy.
Diabetic retinopathy is a common complication of diabetes and a leading cause of visual impairment and blindness. Research has established the importance of blood glucose control to prevent development and progression of the ocular complications of diabetes. Simultaneous blood pressure control has been advocated for the same purpose, but findings reported from individual studies have supported varying conclusions regarding the ocular benefit of interventions on blood pressure. ⋯ Hypertension is a well-known risk factor for several chronic conditions in which lowering blood pressure has proven to be beneficial. The available evidence supports a beneficial effect of intervention to reduce blood pressure with respect to preventing diabetic retinopathy for up to 4 to 5 years. However, the lack of evidence to support such intervention to slow progression of diabetic retinopathy or to prevent other outcomes considered in this review, along with the relatively modest support for the beneficial effect on incidence, weakens the conclusion regarding an overall benefit of intervening on blood pressure solely to prevent diabetic retinopathy.
-
Cochrane Db Syst Rev · Jan 2015
ReviewDopamine transporter imaging for the diagnosis of dementia with Lewy bodies.
Dementia with Lewy bodies (DLB) is a common cause of neurodegenerative dementia of old age. Its accurate recognition can be important in clinical management and is essential for the development of disease-modifying treatments. The current clinical diagnostic criteria are limited particularly by relatively poor sensitivity. Dopamine transporter (DAT) imaging using single-photon emission computed tomography (SPECT) is the most highly developed supplementary test for DLB, and is now incorporated as a suggestive feature in the consensus diagnostic criteria. However, there is uncertainty about its accuracy and its place in clinical practice. It is most commonly used in people who are already suspected of having DLB. ⋯ Only one study has used a neuropathological reference standard to assess the accuracy of DAT imaging for the diagnosis of DLB. The small size of the included study means that sensitivity and specificity estimates are imprecise. However, data from this study suggest that DAT imaging is more accurate than clinical diagnosis. Clinical diagnosis is therefore unsuitable to use as a reference standard for assessing the accuracy of DAT imaging.No studies using a neuropathological reference standard have directly addressed the common clinical scenario where the use of DAT imaging is considered as a diagnostic test in a person with possible DLB, or assessed the accuracy of DAT imaging in people with mild dementia. However, the data from the included study suggest that, where there is moderately severe dementia and a strong pre-existing suspicion of DLB (probable DLB), then a normal (123)I-FP-CIT SPECT scan may be an accurate means of excluding the diagnosis.Semiquantitative ratings of (123)I-FP-CIT SPECT scans appeared to be more accurate than visual ratings in all analyses.
-
Cochrane Db Syst Rev · Jan 2015
ReviewDopamine transporter imaging for the diagnosis of dementia with Lewy bodies.
Dementia with Lewy bodies (DLB) is a common cause of neurodegenerative dementia of old age. Its accurate recognition can be important in clinical management and is essential for the development of disease-modifying treatments. The current clinical diagnostic criteria are limited particularly by relatively poor sensitivity. Dopamine transporter (DAT) imaging using single-photon emission computed tomography (SPECT) is the most highly developed supplementary test for DLB, and is now incorporated as a suggestive feature in the consensus diagnostic criteria. However, there is uncertainty about its accuracy and its place in clinical practice. It is most commonly used in people who are already suspected of having DLB. ⋯ Only one study has used a neuropathological reference standard to assess the accuracy of DAT imaging for the diagnosis of DLB. The small size of the included study means that sensitivity and specificity estimates are imprecise. However, data from this study suggest that DAT imaging is more accurate than clinical diagnosis. Clinical diagnosis is therefore unsuitable to use as a reference standard for assessing the accuracy of DAT imaging.No studies using a neuropathological reference standard have directly addressed the common clinical scenario where the use of DAT imaging is considered as a diagnostic test in a person with possible DLB, or assessed the accuracy of DAT imaging in people with mild dementia. However, the data from the included study suggest that, where there is moderately severe dementia and a strong pre-existing suspicion of DLB (probable DLB), then a normal (123)I-FP-CIT SPECT scan may be an accurate means of excluding the diagnosis.Semiquantitative ratings of (123)I-FP-CIT SPECT scans appeared to be more accurate than visual ratings in all analyses.
-
Cochrane Db Syst Rev · Jan 2015
ReviewSound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.
Infants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home or office environments and contains disturbing noises of short duration and at irregular intervals. There are competing auditory signals that frequently challenge preterm infants, staff and parents. The sound levels in NICUs often exceed the maximum acceptable level of 45 decibels (dB), recommended by the American Academy of Pediatrics. Hearing impairment is diagnosed in 2% to 10% of preterm infants versus 0.1% of the general paediatric population. Noise may cause apnoea, hypoxaemia, alternation in oxygen saturation, and increased oxygen consumption secondary to elevated heart and respiratory rates and may, therefore, decrease the amount of calories available for growth. Elevated levels of speech are needed to overcome the noisy environment in the NICU, thereby increasing the negative impacts on staff, newborns, and their families. High noise levels are associated with an increased rate of errors and accidents, leading to decreased performance among staff. The aim of interventions included in this review is to reduce sound levels to 45 dB or less. This can be achieved by lowering the sound levels in an entire unit, treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled, or reducing the sound levels that reaches the individual infant by using earmuffs or earplugs. By lowering the sound levels that reach the neonate, the resulting stress on the cardiovascular, respiratory, neurological, and endocrine systems can be diminished, thereby promoting growth and reducing adverse neonatal outcomes. ⋯ To date, only 34 infants have been enrolled in a randomised controlled trial (RCT) testing the effectiveness of reducing sound levels that reach the infants' ears in the NICU. Based on the small sample size of this single trial, we cannot make any recommendations for clinical practice. Larger, well designed, conducted and reported trials are needed.