Usual Care Physiotherapy During Acute Hospitalization in Subjects Admitted to the ICU: An Observational Cohort Study.
Physiotherapists play an important role in the provision of multidisciplinary team-based care in the ICU. No studies have reported usual care respiratory management or usual care on the wards following ICU discharge by these providers. This study aimed to investigate usual care physiotherapy for ICU subjects during acute hospitalization. ⋯ Subjects received a higher frequency of physiotherapy in the ICU than on acute wards. Consensus is required to ensure consistency in data collection internationally to facilitate comparison of outcomes.
-
Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. ⋯ Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures.
-
Positive expiratory pressure (PEP) and CPAP are used to enhance breathing parameters such as functional residual capacity (FRC) in patients. Studies comparing effects of PEP and CPAP on FRC are few and variable. One reason for this may be that sophisticated equipment, not suitable in the clinical setting, is required. Because total lung capacity (TLC) consists of inspiratory capacity (IC) and FRC, a change in IC should result in a corresponding change in FRC given constant TLC. We aimed to evaluate the effects of different PEP and CPAP devices on IC as an indirect measure of induced changes in FRC from these devices in healthy subjects. ⋯ Provided that TLC is constant, we found that measurements of changes in IC could be used as an indirect measure of changes in FRC in healthy subjects. All investigated breathing devices except the PEP bottle decreased IC, as an indirect measure of increased FRC.
-
Optimization of factors affecting aerosol delivery during mechanical ventilation in the pediatric population is important. We hypothesized that increasing the tidal volume (V(T)), using a vibrating mesh nebulizer, and placing the nebulizer at the ventilator would increase lung dose/delivery efficiency. ⋯ Optimization of inhaled drug delivery during pediatric mechanical ventilation should include careful selection of the type of delivery device and its placement in the ventilator circuit. Increasing V(T) during nebulization did not increase lung dose/delivery efficiency.
-
Previous research has demonstrated a positive linear correlation between flow delivered and airway pressure generated by high-flow nasal therapy. Current practice is to use flows over a range of 30-60 L/min; however, it is technically possible to apply higher flows. In this study, airway pressure measurements and electrical impedance tomography were used to assess the relationship between flows of up to 100 L/min and changes in lung physiology. ⋯ Measured airway pressure and lung impedance increased linearly with increased gas flow. Observed airway pressures were in the range used clinically with face-mask noninvasive ventilation. Developments in delivery systems may result in this therapy being an acceptable alternative to face-mask noninvasive ventilation.