Respiratory care
-
Randomized Controlled Trial
Clinical Efficacy of Vibrating Mesh and Jet Nebulizers With Different Interfaces in Pediatric Subjects With Asthma.
Nebulizers are commonly used in emergency departments to deliver bronchodilators to children with asthma exacerbations. However, no clinical study comparing a vibrating mesh nebulizer with a jet nebulizer is available in this patient population. The purpose of this study was to compare the clinical efficacy of a vibrating mesh nebulizer to a jet nebulizer combined with a mouthpiece or mask in children with asthma exacerbations admitted to the emergency department. ⋯ Subjects treated with a vibrating mesh nebulizer required significantly fewer treatments and less time to achieve a mild asthma score. In subjects with a mask interface, the vibrating mesh nebulizer significantly reduced the probability of admission compared to jet nebulizer. (ClinicalTrials.gov registration NCT02774941.).