Respiratory care
-
Multicenter Study Clinical Trial Observational Study
Predictors of Extubation Failure Related to Aspiration and/or Excessive Upper Airway Secretions.
Extubation failure may have several causes, including swallowing dysfunction, aspiration, and excessive upper airway secretions. We hypothesized that a bedside global swallowing pattern assessment including 9 criteria (volume of pharyngeal secretions, 5 swallowing motor items, swallowing reflex, and 2 gag reflexes) performed prior to extubation could identify patients at risk of extubation failure. ⋯ In subjects with prolonged ventilation, the presence of one or both gag reflexes could predict a reduction in extubation failure related to aspiration or excessive upper airway secretions. (Clinical trials.gov registration NCT00780078.).
-
Lung-protective ventilation targeting low tidal volumes and plateau pressures is the mainstay of therapy in patients with ARDS. This ventilation strategy limits pulmonary strain, inflammation, and injury, but it may be associated with profound hypercapnic acidosis. In such conditions, extracorporeal CO2 removal can attenuate or normalize hypercapnia and may even facilitate ultraprotective ventilation. ⋯ Systems adapted from conventional renal replacement platforms with blood flows < 500 mL/min can achieve significant CO2 elimination. Therefore, incorporating low-flow extracorporeal CO2 removal in a continuous renal replacement therapy circuit is an attractive therapeutic option. We reviewed the relevant literature on combining extracorporeal CO2 removal with continuous renal replacement therapy.
-
Lung function parameters are used as signs in the diagnosis and evaluation of asthma; however, their sensitivity and specificity are not ideal. We calculated and combined angle β with lung function parameters to identify the ideal indicator. ⋯ Angle β was a useful indicator for assessing airway obstruction. Furthermore, angle β combined with FEV1, FEV1/FVC%, FEF25%, FEF50%, and FEF75% can enhance the sensitivity and specificity of airway obstruction evaluations.
-
The 6-min walk test (6MWT) is a well-established functional exercise capacity test in lung transplant candidates. This study aimed to investigate the construct validity of the 1-min sit-to-stand test (1-min STS) as a marker of exercise capacity and knee extensor strength in lung transplantation candidates. ⋯ The 1-min STS is a valid functional exercise capacity test in lung transplantation candidates. Due to its ease of application, clinical practitioners may consider using the 1-min STS in situations when the 6MWT cannot be performed. Our pilot study may stimulate future research, including a head-to-head comparison between the 6MWT and 1-min STS in a large patient cohort including post-lung transplantation-monitoring.
-
Review Meta Analysis
Effects of Inspiratory Muscle Training in Older Adults.
Inspiratory muscle training (IMT) has been widely applied to different populations, including the general population of older adults. In addition to increasing inspiratory muscle strength, other benefits of IMT in the health of this population have been reported. The primary aim of this study was to review the effects of IMT on the general parameters of health (eg, respiratory, functional, physical, and other variables) in older adults (≥ 60 y), and the secondary aim was to analyze the main IMT protocol used in the studies. ⋯ The reviewed studies revealed a positive trend for the effectiveness of IMT in improving inspiratory muscle performance in elderly subjects. More randomized studies are needed to evaluate other outcomes (eg, functional capacity, exercise capacity, cardiac autonomic control, quality of life, and others) to provide robust evidence that this training modality can promote improvements in health parameters in this population. In addition, the usual IMT prescription in this population is based on sets and repetitions, of mild to moderate intensity, performed on most days of the week, for ≥ 4 weeks.