Burnout is a major challenge in health care, but its prevalence has not been evaluated in practicing respiratory therapists (RTs). The purpose of this study was to identify RT burnout prevalence and factors associated with RT burnout. ⋯ Burnout was common among the RTs in the midst of the COVID-19 pandemic. Good leadership was protective against burnout, whereas inadequate staffing, an inability to complete work, and a burnout climate were associated with burnout.
-
The growing number of patients on home mechanical ventilation has driven considerable progress in the performance and functionality of ventilators, with features comparable with those used in the ICU. However, a publication gap exists in the evaluation and comparison of their performance and each ventilator choice depends on machine characteristics defined by manufacturers. ⋯ Great variability in terms of technical performance was observed among the 8 home-care ventilators analyzed. Asynchronies became a major issue when home mechanical ventilation was used under higher pressure-support values and lower muscle efforts. Our results may prove to be useful in helping choose the best suited machine based on a patient's clinical therapy needs.
-
Patients with coronavirus disease 2019 (COVID-19) often develop acute hypoxemic respiratory failure and receive invasive mechanical ventilation. Much remains unknown about their respiratory mechanics, including the trajectories of pulmonary compliance and [Formula: see text]/[Formula: see text], the prognostic value of these parameters, and the effects of prone positioning. We described respiratory mechanics among subjects with COVID-19 who were intubated during the first month of hospitalization. ⋯ Respiratory mechanics of the subjects with COVID-19 who were on mechanical ventilation were characterized by persistently low respiratory system compliance and [Formula: see text]/[Formula: see text], similar to ARDS due to other etiologies. The [Formula: see text]/[Formula: see text] was more tightly associated with mortality than with compliance.
-
The purpose of this study was to evaluate how factors (ambient temperature, shaking the inhaler before use, suspension of the inhaler in water, and the variation over the lifetime of the inhaler) affect the particle-size distributions from albuterol HFA inhalers. ⋯ Temperature made a difference, with cold inhalers producing a lower fine-particle fraction. The early portion of the inhaler had a better fine-particle fraction than the middle and end of the inhaler's lifespan. We could not demonstrate that shaking the inhaler had a significant effect on the fine-particle fraction. Submerging the inhaler in water significantly reduced the fine-particle fraction.
-
In a spontaneously breathing 3-dimensional printed nasal airway model of a preterm neonate, CPAP performance was assessed based on delivered pressure, oxygen level, and humidity at different settings. ⋯ Performance testing of the bubble CPAP system demonstrated accurate control of CPAP and oxygen concentration with humidity levels suitable for premature newborns on noninvasive support.