Respiratory care
-
Randomized Controlled Trial
Bronchodilator Efficacy of High-Flow Nasal Cannula in COPD: Vibrating Mesh Nebulizer Versus Jet Nebulizer.
Jet nebulizers are commonly used for bronchodilator therapy in COPD. High-flow nasal cannula with vibrating mesh nebulizer (HFNC-VMN) is a recently developed system; however, few studies have compared the efficacy of bronchodilator administration via HFNC-VMN to jet nebulizer in stable COPD. This study aimed to compare the effect of salbutamol administered via HFNC-VMN versus jet nebulizer on airway and lung function in subjects with stable COPD. ⋯ Bronchodilator therapy via HFNC-VMN was not inferior to jet nebulizer for subjects with stable COPD and can significantly improve airway oscillometry mechanics and decrease nebulization time compared to jet nebulizer.
-
Randomized Controlled Trial
Effect of a Conical-PEP Mask on Exercise in Subjects With COPD.
Dynamic hyperinflation (DH) is a major pathophysiology of COPD that is directly related to dyspnea and exercise intolerance. Positive expiratory pressure (PEP) might reduce DH and dyspnea during exercise, but at present, there is insufficient evidence to conclude whether it is beneficial for DH, dyspnea, and exercise capacity in COPD. ⋯ Breathing with a 5 cm H2O conical-PEP mask improved exercise time (median 27.1% [0.6-52.9]) in subjects with COPD. The improvement in exercise with the conical-PEP mask was associated with slower development of breathlessness, possibly due to delays in DH development.
-
Randomized Controlled Trial
Alleviation of Dyspnea and Changes in Physical Activity Level by Blowing Air to the Face with a Fan.
Dyspnea is an unpleasant subjective symptom and is associated with decreased physical activity level (PAL). Effect of blowing air toward the face has received a great deal of attention as a symptomatic therapy for dyspnea. However, little is known about the duration of its effect and its impact on PAL. Therefore, this study aimed to measure dyspnea severity and changes in dyspnea and PALs with air blasts to the face. ⋯ No significant difference was observed for dyspnea and PALs in subjects after blowing air toward their own faces with a small fan for 3 weeks at home. Disease variability and impact of protocol violations were high due to small number of cases. Further studies with a design focused on subject protocol adherence and measurement methods are required to understand impact of air flow on dyspnea and PAL.
-
Randomized Controlled Trial
Automated Oxygen Titration During CPAP and Noninvasive Ventilation in Healthy Subjects With Induced Hypoxemia.
Automated oxygen titration to maintain a stable SpO2 has been developed for spontaneously breathing patients but has not been evaluated during CPAP and noninvasive ventilation (NIV). ⋯ In this proof-of-concept study, automated oxygen titration was used during CPAP and NIV. The performances to maintain the SpO2 target were significantly better compared to manual oxygen titration in the setting of this study protocol. This technology may allow decreasing the number of manual interventions for oxygen titration during CPAP and NIV.