BMC anesthesiology
-
Multicenter Study Observational Study
Feasibility and safety of dilatational tracheotomy using the rigid endoscope: a multicenter study.
Fiberoptic tracheo-bronchoscopy is the most commonly used procedure for percutaneous dilational tracheotomy (PDT). However, PDT can be associated with major complications, including death. Furthermore it is unclear, whether the tracheal ring fractures may contribute to the development of tracheal stenosis after PDT nor whether tracheal ring fractures can be prevented by using a rigid endoscope for this procedure. The purpose of this study was to evaluate the feasibility of and the incidence of complications for PDT using the rigid tracheotomy endoscope (TED). ⋯ The use of TED in PDT is feasible, and the incidence of complications and adverse events was comparable with that of PDT using the flexible endoscope. Tracheal ring fractures in PDT cannot be avoided by the use of a rigid endoscope. With TED, the airway always remains open thus the use of jet ventilation via the TED during PDT is possible.