Korean journal of anesthesiology
-
Pain is difficult to investigate and difficult to treat, in part, because of problems in quantification and assessment. The use of opioids, combined with classic anesthetics to maintain hemodynamic stability by controlling responses to intraoperative painful events has gained significant popularity in the anesthetic field. ⋯ Over the past two decades, many concerns have arisen with respect to opioid-induced hyperalgesia (OIH), which is the paradoxical effect wherein opioid usage may decrease pain thresholds and increase atypical pain unrelated to the original, preexisting pain. This brief review focuses on the evidence, mechanisms, and modulatory and pharmacologic management of OIH in order to elaborate on the clinical implication of OIH.
-
Korean J Anesthesiol · Nov 2014
Cerebral blood flow change during volatile induction in large-dose sevoflurane versus intravenous propofol induction: transcranial Doppler study.
The impact of volatile induction using large-dose sevoflurane (VI-S) on cerebral blood flow has not been well investigated. The present study compared the changes in cerebral blood flow of middle cerebral artery using transcranial Doppler (TCD) during VI-S and conventional induction using propofol. ⋯ VI-S using large-dose sevoflurane increases cerebral blood flow resulting in luxury cerebral flow-metabolism mismatch, while conventional propofol induction maintains cerebral flow-metabolism coupling. This mismatch in VI-S may have to be considered in clinical application of VI-S.
-
Korean J Anesthesiol · Nov 2014
A comparison of i-gel™ and LMA Supreme™ in anesthetized and paralyzed children.
Both the i-gel™ (i-gel) and LMA Supreme™ (Supreme) are new single-use second generation supraglottic airway devices available in pediatric sizes. This study was designed to investigate the i-gel in comparison with the Supreme in children undergoing general anesthesia. ⋯ Both the i-gel and Supreme provided a satisfactory airway during general anesthesia in children. Compared to the Supreme, the i-gel demonstrated a higher oropharyngeal leak pressure, longer time for insertion, and a greater number of airway manipulations during anesthesia.
-
Korean J Anesthesiol · Nov 2014
Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery?
The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery. ⋯ In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.
-
Korean J Anesthesiol · Nov 2014
Topographic pattern of the brachial plexus at the axillary fossa through real-time ultrasonography in Koreans.
The ability to explore the anatomy has improved our appreciation of the brachial anatomy and the quality of regional anesthesia. Using real-time ultrasonography, we investigated the cross-sectional anatomy of the brachial plexus and of vessels at the axillary fossa in Koreans. ⋯ Using real-time ultrasonography, we found that the anatomical pattern of the major nerves in Koreans was about 80% of the frequent position of individual nerves, 90.8% of the single AA, and 87% of multiple veins around the AA.