Physics in medicine and biology
-
The isocentric three-dimensional performance of the Elekta Precise Table was investigated. A pointer was attached to the radiation head of the accelerator and positioned at the geometric rotational axis of the head. A USB-microscope was mounted on the treatment tabletop to measure the table position relative to the pointer tip. ⋯ A new method to ensure optimal positioning of the table relative to the accelerator is presented. This method cannot eliminate systematic errors completely. To eliminate systematic errors we suggest that geometric and elastic models of the table and accelerator gantry arm are incorporated in the dose planning system.
-
Comparative Study
Risk of second malignant neoplasm following proton versus intensity-modulated photon radiotherapies for hepatocellular carcinoma.
Hepatocellular carcinoma (HCC), the sixth most common cancer in the world, is a global health concern. Radiotherapy for HCC is uncommon, largely because of the likelihood of radiation-induced liver disease, an acute side effect that is often fatal. Proton beam therapy (PBT) and intensity-modulated radiation therapy (IMRT) may offer HCC patients a better option for treating the diseased liver tissue while largely sparing the surrounding tissues, especially the non-tumor liver. ⋯ Risk models of SMN incidence were taken from the literature. The predicted absolute lifetime attributable risks of SMN incidence were 11.4% after PBT and 19.2% after IMRT. The results of this study suggest that using proton beams instead of photon beams for radiotherapy may reduce the risk of SMN incidence for some HCC patients.
-
Routine quality control of ultrasound scanners and transducers is important for maintaining image quality. Our experience suggests that artefact and uniformity evaluation is the most effective single phantom test for detecting equipment problems. Current methods for assessing ultrasound images for artefacts have important limitations. ⋯ With minimal training, reproducible clips were obtained by clinical sonographers with low inter- and intra-operator dependence, for a range of transducers models. The flexible scanning surface of the liquid phantom allows complete rapid coupling of all transducers. Due to its ease of use and low cost this liquid phantom appears superior to rigid phantoms for assessment of non-uniformity artefacts, and should allow clinical practices to perform routine artefact assessments of all ultrasound scanners and transducers.