Research in veterinary science
-
The validity of behavioural indicators to assess unconsciousness under different slaughter conditions is under (inter)national debate. The aim of this study was to validate eyelid-, withdrawal-, threat reflex and rhythmic breathing as indicators to assess unconsciousness in sheep. Sheep were monitored during repeated propofol anaesthesia (n=12) and during non-stunned slaughter (n=22). ⋯ Threat reflex and rhythmic breathing correlated with EEG activity during propofol anaesthesia whilst absence of non-rhythmic breathing or threat reflex indicated unconsciousness. None of the behavioural indicators correlated with EEG activity during non-stunned slaughter. Absence of regular breathing and eyelid reflex was observed 00:27±00:12 min and 00:59±00:17 min (mean±SD) respectively after animals were considered unconscious, indicating that absence of regular breathing and eyelid reflex are distinctly conservative indicators of unconsciousness during non-stunned slaughter in sheep.