The Journal of extra-corporeal technology
-
J Extra Corpor Technol · Mar 2005
Randomized Controlled Trial Clinical TrialClinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting.
In an attempt to make cardiopulmonary bypass (CPB) less traumatic for patients undergoing cardiac surgery, extracorporeal circuits (ECC) have been modified to achieve this goal. Poly(2-methoxyethylacrylate) (PMEA, X-coating) is a new polymer coating used in the ECC. PMEA studies have shown excellent biocompatibility with the components of blood. ⋯ The authors evaluated PMEA-coating by measuring clinical outcomes, such as ventilation time, ICU and hospital lengths of stay, and homologous blood utilization. PMEA patients trended towards less homologous blood transfusions, which helped save an average of $83.41 per patient. Further clinical studies are needed to evaluate the benefits of this new polymer coating.
-
J Extra Corpor Technol · Mar 2005
Randomized Controlled Trial Comparative Study Clinical TrialTemperature inaccuracies during cardiopulmonary bypass.
Cerebral hyperthermia caused by perfusate temperature greater than 37 degrees C during the rewarming phase of CPB has been linked to postoperative neurologic deficits. The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor. Seventeen patients undergoing CPB were divided into four groups, each with a different temperature probe coupled to the oxygenator. ⋯ The accuracy of the CDI temperature drastically improved when the flow-through the sensor was increased to approximately 400 mL/min. Thus, the perfusionist must ensure adequate flow through the sensor in order for the temperature mechanism to function properly. Finally, the perfusionist can prevent cerebral hyperthermia by not allowing water temperature to exceed 37 degrees C, when using a coupled temperature measurement system.
-
J Extra Corpor Technol · Mar 2005
Is platelet function as measured by Thrombelastograph monitoring in whole blood affected by platelet inhibitors?
Platelet inhibitors, especially the glycoprotein (GP) IIb/IIIa receptor antagonists, have demonstrated their effectiveness in reducing the acute ischemic complications of percutaneous coronary intervention (PCI) and in improving clinical outcomes in patients with acute coronary crisis. Three common platelet inhibitors observed in emergent cardiopulmonary bypass (CPB) for failed PCI are abciximab, eptifibatide, and tirofiban. An in vitro model was constructed in two parts to determine whether platelet aggregation inhibition induced by platelet inhibitors would be demonstrated by the Thrombelastograph (TEG) monitor when compared with baseline samples with no platelet inhibitor. ⋯ Samples treated with abciximab were comparable to control values for all parameters measured. Although statistical significance could be demonstrated with some parameters, sensitivity was only observed at increased doses and was not seen with all agents tested. In our in vitro model, the TEG monitor was unable to demonstrate clinically significant differences in platelet function and may not be reflective of platelet function in samples which have been treated with these GP IIb/IIIa inhibitors.
-
J Extra Corpor Technol · Mar 2005
Case ReportsExtracorporeal membrane oxygenation and CO2 removal in an adult after near drowning.
Near drowning is a common event among otherwise healthy young people. The development of ARDS in the setting may significantly increase mortality. ⋯ It may be especially successful in those victims with single organ injury. We report the use of ECMO in a young adult with ARDS and pneumonia after near drowning.
-
J Extra Corpor Technol · Mar 2005
Comparative StudyThrombelastograph (TEG) analysis of platelet gel formed with different thrombin concentrations.
Autologous blood transfusion is the safest and most successful way to decrease transfusion-related risks such as postoperative infections, allo-immunization, and short- and long-term immunosuppression. In addition, these fibrin sealants are known to provide coagulation support at the surgical site and act as an adjunct to the control of postoperative bleeding. The physical formation of autologous platelet fibrin gel clot is dependent on both the common pathway of the coagulation cascade and platelet activation. ⋯ The results showed that thrombin concentration did not affect the MA, tMA, CI, or angle as measured by the TEG analyzer. The null hypothesis was accepted. Based on a one-way analysis of variance test for MA, tMA, CI, and angle there was no significant statistical difference for the TEG samples in this experiment as reported with a 95% confidence interval.