Canadian Anaesthetists' Society journal
-
Randomized Controlled Trial Clinical Trial
Effect of lateral position and volume on the spread of epidural anaesthesia in the parturient.
The effect of lateral positioning and the volume of drug injected on the spread of epidural anaesthesia was assessed in 131 healthy parturients. Epidural injection for anaesthesia was done at the L3-4 interspace and a catheter was inserted into the epidural space after injection of the drug. The patients were randomly assigned to four groups. ⋯ Maintenance of the lateral position after induction of epidural anaesthesia is compatible with satisfactory analgesia for labour. Twelve ml bupivacaine 0.25 per cent provides better analgesia than 6 ml bupivacaine 0.5 per cent although the same mass is injected. The quality of analgesia is improved by turning the patients to the contralateral side after injection of 12 ml bupivacaine 0.25 per cent.