Scientific reports
-
Randomized Controlled Trial Multicenter Study
An abluminal biodegradable polymer sirolimus-eluting stent versus a durable polymer everolimus-eluting stent in patients undergoing coronary revascularization: 3-year clinical outcomes of a randomized non-inferiority trial.
The Cordimax stent has proved non-inferior to the Cypher Select durable polymer sirolimus-eluting stent for the primary endpoint of angiographic in-stent late luminal loss and in-stent mean diameter stenosis at 9 months. The trial was designed to compare the efficacy and safety of the Cordimax stent with the Xience V stent in patients undergoing coronary revascularization. This randomized, multicenter trial enrolled 3697 patients treated with Cordimax stent (2460 patients) and Xience V stent (1237 patients). ⋯ The incidence of target lesion revascularization was low in Cordimax group compared with Xience V group (3.6% versus 5.1%, P = 0.03). There were no differences between Cordimax and Xience V in terms of Cardiac death (0.3% versus 0.4%, P = 0.70), myocardial infarction (1.2% versus 0.9%, P = 0.37), and the stent thrombosis (0.4% versus 0.6%, P = 0.61). In conclusion, safety and efficacy outcomes of Cordimax stent were non-inferior to the Xience V stent 3 years after stent implantation.