Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
-
We have recently shown that a contact force (CF)-guided ablation protocol respecting region-specific criteria of lesion contiguity and lesion depth ('CLOSE' protocol) is associated with high incidence of acute durable pulmonary vein (PV) isolation (PVI) and a high single-procedure arrhythmia-free survival at 1 year. In the present study, we compared efficiency, safety, and efficacy of 'CLOSE'-guided PVI to conventional CF-guided PVI (CONV-CF). ⋯ 'CLOSE'-guided PVI improves procedural and 1 year outcome in CF-guided PVI while shortening procedure time. Improvement cannot be explained by differences in CF variability and is most likely due to the strict application of criteria for contiguity and ablation index. A randomized controlled trial is needed to exclude the possible contribution of a learning curve.