First prospective, multi-centre clinical experience with a novel left ventricular quadripolar lead.
Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure. ⋯ The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11% of patients in the study suffered PNS on all conventional bipolar vectors.
-
Multicenter Study
Feasibility of percutaneous implantation of transapical endocardial left ventricular pacing electrode for cardiac resynchronization therapy.
Failure of coronary sinus lead implantation for resynchronization therapy requires alternative approaches. For such events we have developed a transapical implantation technique as a feasible alternative. We report the outcome of this technique and its evolution from a minithoracotomy to a percutaneous approach. ⋯ Twelve patients have >1 year follow-up; all have sustained and significant improvement in LV dimensions (diastolic Δ4.2 ± 2.9, systolic Δ7.2 ± 5.8 mm), ejection fraction (Δ9.5 ± 9.6%), and functional status (Δ1.1 ± 0.3). Transapical placement of LV endocardial pacing lead is an effective alternative strategy for cardiac resynchronization. A closed-chest, percutaneous approach is feasible and should offer even less invasive intervention.
-
Multicenter Study Clinical Trial
Safety, efficacy, and performance of new discrimination algorithms to reduce inappropriate and unnecessary shocks: the PainFree SST clinical study design.
Implantable cardioverter defibrillator (ICD) shock therapy improves survival of patients at risk for sudden cardiac death. The high sensitivity of ICDs to detect tachycardia events is accompanied by reduced specificity resulting in inappropriate and unnecessary shocks. Up to 30% of ICD patients may experience inappropriate shocks, which are most commonly caused by lead noise, oversensing of T-waves, and supraventricular tachycardias. The new Protecta ICD and cardiac resynchronization therapy devices have been designed to minimize inappropriate and unnecessary shocks through novel SmartShock(TM) technology algorithms targeting these causes. ⋯ Inappropriate and unnecessary shock delivery remains a significant clinical issue for patients receiving device therapies, which has considerable consequences for patients and the healthcare system. The PainFree SST study will investigate the ability of new algorithms to reduce inappropriate shocks. Results from this study are expected in mid-2013.
-
To assess the clinical presentation and acute management of patients with transient loss of consciousness (T-LOC) in the emergency department (ED). ⋯ Adherence to clinical guidelines for syncope management was low; many diagnostic tests were performed with low diagnostic yield. Important differences were observed between syncope diagnoses at the ED and by SC decision.
-
Multicenter Study Comparative Study
Intracardiac impedance monitors stroke volume in resynchronization therapy patients.
Monitoring of haemodynamic parameters or surrogate parameters of the left ventricle is especially important for patients under cardiac resynchronization therapy (CRT). Intracardiac impedance reflects left ventricular (LV) volume changes well in animal models. Since it is unknown whether this also holds in humans with heart failure (HF), we examined the correlation of LV intracardiac impedance with haemodynamic parameters in CRT patients for different positions of the LV lead. ⋯ In HF patients, a strong correlation between changes in intracardiac impedance and LV SV was found. Typical LV lead implant positions have been tested and all appear to be suitable for this method of LV volume monitoring.