Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
-
We sought to compare the effectiveness and safety of high-power short-duration (HPSD) radiofrequency ablation (RFA) with conventional RFA in patients with atrial fibrillation (AF). ⋯ High-power short-duration RFA was associated with better procedural effectiveness when compared with conventional RFA with comparable safety and shorter procedural duration.
-
There is growing evidence that magnetic resonance imaging (MRI) scanning in patients with non-conditional cardiac implantable electronic devices (CIEDs) can be performed safely. Here, we aim to assess the safety of MRI in patients with non-conditional CIEDs. ⋯ This meta-analysis affirms the safety of MR imaging in non-conditional CIEDs with no death or implantable cardioverter-defibrillator shocks and extremely low incidence of lead or device-related complications.
-
Review Meta Analysis
The impact of adjunctive complex fractionated atrial electrogram ablation and linear lesions on outcomes in persistent atrial fibrillation: a meta-analysis.
In persistent atrial fibrillation (PsAF), success rates for pulmonary vein isolation (PVI) alone are limited and additional substrate modification is often performed. The two most widely used substrate-based strategies are the ablation of complex fractionated atrial electrograms (CFAE) and left atrial linear ablation (LALA) at the roof and mitral isthmus. However, it is unclear whether adjunctive CFAE ablation or LALA add significant benefit to PVI alone. We performed a meta-analysis to better gauge the benefit of adjunctive CFAE ablation and LALA in PsAF. ⋯ In PsAF, the addition of CFAE ablation or LALA, in comparison with PVI alone, offers no significant improvement in arrhythmia-free survival. Furthermore, they are associated with increases in both procedural and fluoroscopy times. The optimal ablation strategy for PsAF is currently unclear and needs further refinement.
-
Review Meta Analysis
Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis.
Infectious complications after cardiac implantable electronic device (CIED) implantation are increasing over time and are associated with substantial mortality and healthcare costs. The aim of this study was to systematically summarize the literature on risk factors for infection after pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy device implantation. Electronic searches (up to January 2014) were performed in PubMed, Scopus, and Web of Science databases. ⋯ Regarding procedure-related factors, post-operative haematoma (OR = 8.46 [4.01-17.86]), reintervention for lead dislodgement (OR = 6.37 [2.93-13.82]), device replacement/revision (OR = 1.98 [1.46-2.70]), lack of antibiotic prophylaxis (OR = 0.32 [0.18-0.55]), temporary pacing (OR = 2.31 [1.36-3.92]), inexperienced operator (OR = 2.85 [1.23-6.58]), and procedure duration (weighted mean difference = 9.89 [0.52-19.25]) were all predictors of CIED infection. Among device-related characteristics, abdominal pocket (OR = 4.01 [2.48-6.49]), epicardial leads (OR = 8.09 [3.46-18.92]), positioning of two or more leads (OR = 2.02 [1.11-3.69]), and dual-chamber systems (OR = 1.45 [1.02-2.05]) predisposed to device infection. This systematic review on risk factors for CIED infection may contribute to developing better infection control strategies for high-risk patients and can also help risk assessment in the management of device revisions.
-
Review Meta Analysis
Cardiac-resynchronization therapy in patients with systolic heart failure and QRS interval ≤130 ms: insights from a meta-analysis.
Cardiac-resynchronization therapy (CRT) reduces morbidity and mortality in patients with chronic systolic heart failure (SHF) and a wide QRS complex. It is unclear whether the same benefit extends to patients with QRS duration (QRSd) <130 ms. ⋯ Cardiac-resynchronization therapy defibrillator has no impact on SHF mortality and SHF hospitalization in patients with systolic HF with QRS duration ≤130 ms and is associated with higher all-cause mortality in comparison with ICD therapy.