Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
-
The aim of our study was to investigate the long-term efficacy and safety of transseptal endocardial left ventricular lead implantation (TELVLI). ⋯ The TELVLI is an effective approach for cardiac resynchronization therapy (CRT) however it is associated with a substantial thromboembolic risk (7%).
-
Multicenter Study Observational Study
Association between antithrombotic treatment and outcomes at 1-year follow-up in patients with atrial fibrillation: the EORP-AF General Long-Term Registry.
In recent years, stroke prevention in patients with atrial fibrillation (AF) has radically changed, with increasing use of non-vitamin K antagonist oral anticoagulants (NOACs). Contemporary European data on AF thromboprophylaxis are needed. ⋯ The 1-year follow-up of EORP-AF General Long-Term Registry reported a low occurrence of thromboembolic and haemorrhagic events, although mortality was high. Both VKA and NOACs were associated with a lower risk of all main adverse outcomes. All treatments were associated with a lower risk for CV death and all-cause death.
-
Remote monitoring (RM) has become a new standard of care in the follow-up of patients with implantable pacemakers and defibrillators. While it has been consistently shown that RM enables earlier detection of clinically actionable events compared with traditional in-patient evaluation, this advantage did not translate into improved patient outcomes in clinical trials of RM except one study using daily multiparameter telemonitoring in heart failure (HF) patients. Therefore, this review, focusing on RM studies of implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators in patients with HF, discusses possible explanations for the differences in trial outcomes. ⋯ Furthermore, the technical set-up of RM may have an important impact as a higher level of connectivity with more frequent data transmission can be linked to better outcomes. Finally, there is growing evidence as to the need of effective algorithms ensuring a fast and well-structured clinical response to the events detected by RM. These factors re-emphasize the potential of remote management of device patients with HF and call for continued clinical research and technical development in the field.