Physiological reports
-
Physiological reports · Apr 2016
Randomized Controlled TrialAcute supplementation of N-acetylcysteine does not affect muscle blood flow and oxygenation characteristics during handgrip exercise.
N-acetylcysteine (NAC; antioxidant and thiol donor) supplementation has improved exercise performance and delayed fatigue, but the underlying mechanisms are unknown. One possibility isNACsupplementation increases limb blood flow during severe-intensity exercise. The purpose was to determine ifNACsupplementation affected exercising arm blood flow and muscle oxygenation characteristics. ⋯ BABFwas not different (P = 0.42) during exercise or at end-exercise (NAC: 413 ± 109 mL/min;PLA: 445 ± 147 mL/min). Deoxy-[hemoglobin+myoglobin] and total-[hemoglobin+myoglobin] were not significantly different (P = 0.73 andP = 0.54, respectively) at rest or during exercise between conditions. We conclude that acuteNACsupplementation does not alter oxygen delivery during exercise in men.
-
Physiological reports · Apr 2016
Hyperpolarized 3He magnetic resonance imaging ventilation defects in asthma: relationship to airway mechanics.
In patients with asthma, magnetic resonance imaging (MRI) provides direct measurements of regional ventilation heterogeneity, the etiology of which is not well-understood, nor is the relationship of ventilation abnormalities with lung mechanics. In addition, respiratory resistance and reactance are often abnormal in asthmatics and the frequency dependence of respiratory resistance is thought to reflect ventilation heterogeneity. We acquiredMRIventilation defect maps, forced expiratory volume in one-second (FEV1), and airways resistance (Raw) measurements, and used a computational airway model to explore the relationship of ventilation defect percent (VDP) with simulated measurements of respiratory system resistance (Rrs) and reactance (Xrs). ⋯ The relationships forVDPwith Raw measured using plethysmography (r = 0.79), and model predictions of Rrs>14(r = 0.91,P < 0.0001) and Rrs>9(r = 0.88,P < 0.0001) were significantly stronger (P = 0.005;P = 0.03, respectively) than withFEV1(r = -0.68,P = 0.0001). The slopes for the relationship ofVDPwith simulated lung mechanics measurements were different (P < 0.0001); among these, the slope for theVDP-Xrs0.2relationship was largest, suggesting thatVDPwas dominated by peripheral airway heterogeneity in these patients. In conclusion, as a first step toward understanding potential links between lung mechanics and ventilation defects, impedance predictions were made using a computational airway tree model with simulated constriction of airways related to ventilation defects measured in mild-moderate asthmatics.