Diabetes technology & therapeutics
-
Diabetes Technol. Ther. · Jun 2017
ReviewContinuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
Continuous Glucose Monitoring (CGM) has been demonstrated to be clinically valuable, reducing risks of hypoglycemia and hyperglycemia, glycemic variability (GV), and improving patient quality of life for a wide range of patient populations and clinical indications. Use of CGM can help reduce HbA1c and mean glucose. One CGM device, with accuracy (%MARD) of approximately 10%, has recently been approved for self-adjustment of insulin dosages (nonadjuvant use) and approved for reimbursement for therapeutic use in the United States. ⋯ FDA. Closed-loop control using both insulin and glucagon can reduce risk of hypoglycemia even more. CGM facilitates rigorous evaluation of new forms of therapy, characterizing pharmacodynamics, assessing frequency and severity of hypo- and hyperglycemia, and characterizing several aspects of GV.
-
Diabetes Technol. Ther. · Jun 2017
ReviewContinuous Glucose Monitoring and Global Reimbursement: An Update.
Real-time continuous glucose monitoring has been available for a decade and reimbursement for the technology has been slowly growing. Reasons for the various rates of reimbursement and adoption are explored in this article and the status of country-wide reimbursement is discussed.
-
Diabetes Technol. Ther. · Mar 2017
ReviewAn Expert Opinion on Advanced Insulin Pump Use in Youth with Type 1 Diabetes.
Among children and adolescents with type 1 diabetes mellitus, the use of insulin pump therapy has increased since its introduction in the early 1980s. Optimal management of type 1 diabetes mellitus depends on sufficient understanding by patients, their families, and healthcare providers on how to use pump technology. ⋯ However, this goal is often not met, and appropriate understanding of the full features of pump technology can be lacking. The objective of this review is to provide an expert perspective on the advanced features and use of insulin pump therapy, including practical guidelines for the successful use of insulin pump technology, and other considerations specific to patients and healthcare providers.
-
Diabetes Technol. Ther. · Feb 2016
ReviewContinuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.
The development of accurate and easy-to-use continuous glucose monitoring (CGM) improved diabetes treatment by providing additional temporal information on glycemia and glucose trends to patient and physician. Although CGM enables users to lower their average glucose level without an increased incidence of hypoglycemia, this comes at the price of additional patient effort. Automation of insulin administration, also known as closed-loop (CL) or artificial pancreas treatment, has the promise to reduce patient effort and improve glycemic control. ⋯ Improved continuous glucose sensing technology, miniaturization of electrical devices, and development of algorithms were key in making this possible. Clinical adoption challenges, including device usability and reimbursement, need to be addressed. Time will tell for which patient groups CL systems will be reimbursed and whether these devices can deliver the promise that they hold.