Legal medicine
-
Case Reports Comparative Study
Feasibility of post mortem cardiac proton density weighted fast field echo imaging in two cases of sudden death.
The aim of this work is to investigate and compare cardiac proton density (PD) weighted fast field echo (FFE) post-mortem magnetic resonance (PMMR) imaging with standard cardiac PMMR imaging (T1-weighted and T2-weighted turbo spin-echo (TSE)), postmortem CT (PMCT) as well as autopsy. ⋯ Presented initial results have shown PD-weighted FFE to be a valuable imaging sequence in addition to traditional T2-weighted TSE imaging for blood clots and myocardial haemorrhage with clearer contrast between affected and healthy myocardium.
-
We sought to determine the effect of postmortem ventilation in combination with a suction pump in cases showing penetrating trauma to the chest with haemo- and/or pneumothorax, for better evaluation of the lungs in postmortem computed tomography (PMCT). The study included 6 subjects (1 female, 5 male; age 32-67years) with a penetrating gunshot or stab wound to the chest and consecutive pneumo- and/or haemothorax. The pneumo- and haemothorax were evacuated by a suction pump, and postmortem ventilation was applied using a home care ventilator. ⋯ The bullet channel was apparent in one case; in another case, injury of the pericardium became visible by generating pneumopericardium. The present method is capable of improving evaluation of the postmortem lung in the presence of single stab or gunshot wounds and if there is no severe destruction of the respiratory system and aspiration. Forensic autopsy should still be considered as the gold standard, although in some cases the present method might be helpful, especially where no autopsy is required.
-
Case Reports
3D-MSCT imaging of bullet trajectory in 3D crime scene reconstruction: two case reports.
Postmortem investigations are increasingly assisted by three-dimensional multi-slice computed tomography (3D-MSCT) and have become more available to forensic pathologists over the past 20years. In cases of ballistic wounds, 3D-MSCT can provide an accurate description of the bullet location, bone fractures and, more interestingly, a clear visual of the intracorporeal trajectory (bullet track). ⋯ These case reports present the implementation of tridimensional methods and the results of 3D crime scene reconstruction in two cases. The authors highlight the value of collaborations between police forensic experts and forensic medicine institutes through the incorporation of 3D-MSCT data in a crime scene reconstruction, which is of great interest in forensic science as a clear visual communication tool between experts and the court.