Comparative StudyPreliminary Results of a Novel Hybrid Cage Glenoid Compared to an All-Polyethylene Glenoid in Total Shoulder Arthroplasty.
The aim of this study was to evaluate the preliminary outcomes of a hybrid cage glenoid design in comparison to pegged all-polyethylene glenoid components in anatomic total shoulder arthroplasty (aTSA). ⋯ At minimum two-year follow-up, hybrid cage aTSA components show equal clinical outcomes to UHMWPE pegged glenoids. However, the hybrid cage components had significantly fewer radiolucent lines and less intra-operative blood loss. Additional and longer-term clinical and radiographic follow-up is necessary to confirm these promising early results.
-
Bull Hosp Jt Dis (2013) · Dec 2015
Comparative StudyThe Impact of Posterior Wear on Reverse Shoulder Glenoid Fixation.
Achieving glenoid fixation with posterior bone loss can be challenging. The purpose of this study was to quantify the impact of two different sizes of posterior glenoid defects (10° and 20°) on reverse shoulder arthroplasty (rTSA) glenoid baseplate fixation and determine if utilizing different sizes of posterior augmented baseplates (8° and 16°) with off-axis reaming provides comparable fixation to using a standard baseplate with different amounts of eccentric reaming. ⋯ Both standard baseplates with eccentric reaming and two different sizes of augmented baseplates with off-axis reaming successfully maintained fixation following cyclic loading in composite scapula with corrected 10° and 20° posterior glenoid defects. Augmented glenoids may be more advantageous long-term from a fixation perspective as they preserve more subchondral glenoid bone due to the minimal reaming occurring by the off-axis method. Mid and long-term clinical follow-up comparisons of outcomes are necessary between these two techniques.
-
Bull Hosp Jt Dis (2013) · Dec 2015
Impact of Posterior Wear on Muscle Length with Reverse Shoulder Arthroplasty.
The use of reverse total shoulder arthroplasty (rTSA) in patients with posterior glenoid wear can be challenging. Implanting a baseplate in the correct version may require significant eccentric reaming, which further medializes the joint line and results in greater rotator cuff muscle shortening. To restore the joint line, bone graft may be required, though it is associated with additional risks. ⋯ More anatomic rotator cuff muscle tensioning was observed with augmented glenoid baseplates. The use of posterior augmented glenoid baseplates has the potential to improve stability and better restore active internal and external rotation, a current limitation of rTSA. However, clinical follow-up is necessary to confirm these favorable biomechanical results.
-
Bull Hosp Jt Dis (2013) · Mar 2015
Multicenter Study Comparative StudyCan We Improve Workflows in the OR? A Comparison of Quality Perceptions and Preoperative Efficiency across Institutions in Spine Surgery.
Cost containment and surgical inefficiencies are major concerns for hospitals in this era of declining resources. The primary aim of this investigation was to understand subjective perceptions of perioperative spine surgical quality across three practice settings and to identify potential factors contributing to these perceptions. Subsequently, we objectively evaluated factors that influence the duration of time in which the patient is in the operating room (OR) prior to the surgical incision and assessed the influence of fluoroscopy technician expertise on radiation dose and imaging efficiency. ⋯ Large private and university hospitals had higher surgeon ratings. The university setting was associated with larger and less consistent surgical teams and lower nurse ratings. Surgical staff awareness of the procedure and attention to preoperative tasks specific to the procedure reduced pre-operative time spent in the OR as well as fluoroscopy radiation. These data suggest that nurses and support staff make substantial contributions to overall quality of care, and that leadership and interpersonal coordination are especially important within large teams at teaching hospitals.
-
Bull Hosp Jt Dis (2013) · Mar 2015
Comparative StudyThe Effect of Adductor-Canal-Blockade on Outcome after Medial Unicondylar Knee Arthroplasty A Preliminary Study.
Unicondylar knee arthroplasty (UKA) offers decreased morbidity, faster recovery, better functional outcomes, and equivalent survivorship compared to TKA for certain patients. To fully capture these benefits, regional anesthesia techniques must facilitate rather than compromise patients ability for early postoperative mobilization and safe discharge following UKA. The purpose of this study was to determine whether the predominantly sensory adductor canal blockade (ACB) shortens hospital stay after medial UKA (mUKA). Secondary endpoints were narcotic consumption, steps walked during PT sessions, and total PT sessions required prior to discharge. ⋯ Data from our study suggests that ACB may permit earlier hospital discharge and better participation in PT without compromising the quality of perioperative analgesia. Thus, ACB may represent a promising option for patients undergoing mUKA in terms of improved clinical outcomes, decreased postoperative morbidity, and cost-effectiveness.