American journal of electroneurodiagnostic technology
-
Am J Electroneurodiagnostic Technol · Sep 2011
Case ReportsPreventing position-related brachial plexus injury with intraoperative somatosensory evoked potentials and transcranial electrical motor evoked potentials during anterior cervical spine surgery.
The use of somatosensory evoked potentials (SSEPs) to monitor upper extremity nerves during surgery is becoming more accepted as a valid and useful technique to minimize intraoperative nerve injuries. We present a case illustrating the benefit of utilizing both SSEPs and transcranial electrical motor evoked potentials (TCeMEPs) for preventing position-related injury during surgery. The patient was a 43-year-old male with a history of neck pain, along with numbness and tingling of the upper extremities. ⋯ At two months follow-up, the patient was well with total pain relief and normal upper extremity function when neurological examination was performed. This report demonstrates a case in which intraoperative neurophysiological monitoring was useful in identifying and reversing impending nerve injury during cervical spine surgery. Significant changes were seen in SSEPs as well as TCeMEPs, so we recommend that TCeMEP monitoring be considered as an adjunct to SSEPs for prevention of injury to the brachial plexus.